DEK INFINITY USER MANUAL - 第233页

INFINITY +286 (.( (3, 1* 5(&29(5<352 &('85( Soft ware Ver sion 7 User Manual 7.23 13. On completion the s ystem restarts, the following window is displayed: 14. Select either PC T ype 1 or PC T ype 2 de…

100%1 / 356
INFINITY
+286(.((3,1*
5(&29(5<352&('85(
7.22 User Manual Software Version 7
RECOVERY PROCEDURE
System Description The machines hard disk drive is partitioned to allocate both system and dynamic
disk space.
System information is held on drive C: which holds all the system software
including the Windows NT operating system.
The drive D: contains the machine operating software and the dynamic (change-
able) files such as product, machine configuration and calibration.
It is the files on drive D: which need to be backed up at regular intervals to enable
the machine to be brought back into an up-to-date working state should the
Windows NT operating system or the machine software fail.
Recovery Disk DEK provides an Infinity Software CD-ROM which the engineer can use to
restore the machine or the operating system software should an error occur. The
CD-ROM auto-runs, on-screen prompts provide an easy route to either full or
partial recovery. The option for full or partial recovery depends upon the extent
of the system error reported and whether the engineer deems it necessary to
complete a full or partial recovery.
At the time of machine shipment, the software CD-ROM is burnt with all the
information required to operate the machine, this disk is shipped with the
machine. It should be noted that the product specific files such as CON-
FIG.TXT files, may have changed since the time of shipment. Files that have
been archived can be used to overwrite the files on disk D: as required.
Recovery Procedure To perform a partial or full system recovery carry out the following:
1. Close down Windows.
2. Insert the Infinity Software CD-ROM into the machine PC CD-ROM tray.
3. Turn the mains isolator to OFF.
4. Turn the mains isolator to ON, the DEK set-up program runs.
5. Select C on the keyboard when the message Press C to Continue or
<ESC> to quit recovery is displayed.
NOTE
If a current copy of the product and machine calibration data is not held,
carry out Steps 6-8.
6. Select Option 3 - Backup Product and Calibration Data.
7. Insert a blank formatted floppy disk into the A:drive.
8. Follow the on-screen prompts and copy the machine calibration and product
files to the A:drive.
9. From the main menu, select either Option 1 to replace Windows NT partition
or Option 2 to reload the entire disk and select C on the keyboard.
10.When prompted enter machine serial number and press Return. The Ghost
program now re-writes the Windows NT partition and if selected the DEK
machine software.
11. On completion, remove the CD-ROM from the PC and reboot the machine.
12.Window NT automatically scans both partitions of the hard disk for errors.
INFINITY
+286(.((3,1*
5(&29(5<352&('85(
Software Version 7 User Manual 7.23
13.On completion the system restarts, the following window is displayed:
14.Select either PC Type 1 or PC Type 2 dependent upon the PC fitted to the
printer and select OK, the following window is displayed:
15.Select OK, the following window is displayed:
CD ROM DRIVE
FDD DRIVE
Infinity Configuration
Chose PC Type and press OK
PC Type 1
PC Type 2
OK
Cancel
Information in C:\RTL813~1.REG has been successfully entered into the registry.
Registry Editor
OK
OK
Cancel
Press OK to complete Printer Configuration
or Cancel to Abort
265 Configuration
INFINITY
+286(.((3,1*
5(&29(5<352&('85(
7.24 User Manual Software Version 7
16.Select OK, the following window is displayed:
17.Enter the machine serial number. In the Options box, select Dual Stepper
and the correct camera for the type fitted to the machine. Ensure Fixed Head
is not selected.
18.Select Next, the following window is displayed:
19.Insert the diskette containing the product and calibration data into A:drive
and press OK. The calibration data is now copied onto the machine hard
disk.
20.The machine now initializes.
21.The product files can now be copied onto the machine using Copy Data
function in Housekeeping (see Copy Data in Housekeeping Chapter).
Abort
Next
265 Option Selection
Options
Fixed Head
Machine Serial Number
Single Stepper
Dual Stepper
Green Pulnix
Green Sony
Grey Sony
Camera Type
ProFlow Print Carriage
273394
OK
Cancel
Insert disk containing Calibration data in driveA:
and press OK to load, or Cancel to Abort
265 Configuration