8.18 User Manual Software Version 7
Selecting End Run clears the warning window, the print cycle is aborted and
control is returned to the ready page.
NOTE
If Camera Idle Position is set to Behind Rail and Unload Board Start is set
to Separation, the warning windows appear one after the other in the order
shown above.
Even with Unload Board Start set to Separation, with 2Di enabled it has no
affect, although the warning window and menu bar are still displayed.
19.If the stencil has not been changed the message Screen has not been
changed for this product is displayed, select Use Screen to continue.
20.Select Auto Board.
21.Setup the board and stencil fiducials.
22.Select Inspect Setup. If this option is unavailable, check set prefs for 2D
Inspection enabled. The following message on the operator prompt bar is
displayed, Click on the board representation to add a new site or select
an existing site to edit.
The following 2Di GUI window (example) appears:
CAUTION
FIDUCIAL POSITION. If during the print cycle, the position of board
fiducials are changed, the position of previous inspection sites, (if any)
may be affected. Small changes are automatically compensated for,
however large changes, ie more than 3mm may require sites to be
relearnt.
Auto
Board
Manual
Board
Exit
Step
Open
Cover
Inspect
Setup
Single Exit
INFINITY
',163(&7,21
',163(&7,216(783
Software Version 7 User Manual 8.19
NOTE
If selecting a product file with site listings pre-loaded, a ‘Please Wait’
indicator bar may be displayed whilst all sites are being downloaded.
Edit Global 1. Select Edit Global.
NOTE
Delete Site is only available if at least one site exists already. Next Site and
Previous Site are only available if at least two sites exist already.
The following Edit Global Parameters window is displayed:
2. Enter the parameter values below using the Next, Previous, Incr. and Decr.
keys.
Pre-images to Every
Warning Limit to 20, this can be reduced later in adjust inspect
Blockage Action to Manual Action, this can be changed later in adjust
inspect
Smear Action to Manual Action, this can be changed later in adjust
inspect.
A definition of all 2Di parameters and their values is given at the end of this
chapter.
On completion of successful setup, parameters can be adjusted to suit the
product.
Edit
Global
Edit
Limits
Add
Site
Exit
ADVANCED
ADVANCED
EVERY
0
3
MANUALACTION
MODE 1
MANUALACTION
MODE 2
MANUAL
DISABLED
STENCIL 2DI TYPE
BOARD 2DI TYPE
PRE-IMAGE MODE
MIN SITES/CYCLE
WARNING LIMIT
BLOCKAGE ACTION
BLOCKAGE CLEAN
SMEAR ACTION
SMEAR CLEAN
LOW PASTE ACTION
INSPECTAFTER CLEAN
Edit Global Parameters
NOTE: Advanced Inspection Type option is not available on some machines.
Limit
Options
Next Previous Incr. Decr. Exit
INFINIT
Y
',163(&7,21
',163(&7,216(783
8.20 User Manual Software Version 7
3. Select Limit Options.
These are usually set to enabled. If for any reason a particular inspection
option is not required, set to disabled. If any global limit options are disabled
the corresponding limit sets and parameters are greyed out. These are global
limits, therefore they are active for the whole product. If a particular
inspection is not required for a specific type of site, this can be achieved later
in limit set options for the site.
4. Enter global limit options using Next, Previous, Incr. and Decr. keys.
5. Select Exit.
6. Select Exit.
Limit
Options
Next Previous Incr. Decr. Exit
Global Limit Set Options
Blockage
Smear
Paste
Alignment
Bridging
Volume
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Next Previous Incr. Decr. Exit