DEK INFINITY USER MANUAL - 第263页
INFINITY ',163(& 7,21 ',163(&7,2 16(7 83 Soft ware Ver sion 7 User Manual 8.23 Edit Limits 1. Select Edit L imits . The following window is displayed: 2. Enter parameters using the Next , Previous …

INFINIT
Y
',163(&7,21
',163(&7,216(783
8.22 User Manual Software Version 7
2. Use the keyboard to enter the ID of the new limit set and press Enter.
NOTE
Limit ID may be any name up to 20 characters in length including spaces.
3. Enter parameters using the Next, Previous, Incr. and Decr. keys. A coarse
set of values is shown above.
4. Select Save Limits. The message ‘Saving Fiducial Data - Please Wait
Board data file saved’ is displayed.
5. Select Exit.
6. Select Edit Limits.
7. Go to Step 3 of Edit Limits (next page).
EditLimitParameters
LimitSetID
BlockageWarning
BlockageAlarm
SmearWarning
SmearAlarm
PasteWarning
PasteAlarm
AlignWarning
AlignAlarm
BridgeWarning
BridgeAlarm
VolumeWarning
VolumeAlarm
COARSE
20
25
1.00 sq mm
1.50 sq mm
70
65
0.200mm
0.250mm
0.015mm
0.010mm
80
70
Save
Limits
Next Previous Incr. Decr. Exit
Save
Limits
Next Previous Incr. Decr. Exit
Save
Limits
Next Previous Incr. Decr. Exit
Add
Limits
Edit
Limits
Next
Limit
Previous
Limit
Exit

INFINITY
',163(&7,21
',163(&7,216(783
Software Version 7 User Manual 8.23
Edit Limits 1. Select Edit Limits.
The following window is displayed:
2. Enter parameters using the Next, Previous, Incr. and Decr. keys. A coarse
set of values is shown above
3. Select Limit Options.
These are usually set to enabled. If for any reason a particular inspection is
not required, set to disabled. If any global limit set options are disabled the
corresponding parameters are greyed out. These are limit set options,
therefore they are only active for this particular limit set. If a particular
inspection is not required for the whole product, this can be achieved in
global limit options, under edit globals, earlier in this chapter.
If either blockage or paste is set to disabled, volume is also disabled. Once
volume is disabled by this method it is not automatically enabled should both
blockage and paste be re-enabled. Volume must be selected and set to
enabled.
Add
Limits
Edit
Limits
Next
Limit
Previous
Limit
Exit
EditLimitParameters
LimitSetID
BlockageWarning
BlockageAlarm
SmearWarning
SmearAlarm
PasteWarning
PasteAlarm
AlignWarning
AlignAlarm
BridgeWarning
BridgeAlarm
VolumeWarning
VolumeAlarm
COARSE
20
25
1.00 sq mm
1.50 sq mm
70
65
0.200mm
0.250mm
0.015mm
0.010mm
80
70
Limit
Options
Save
Limits
Next Previous Incr. Decr. Exit
Limit
Options
Save
Limits
Next Previous Incr. Decr. Exit
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Blockage
Smear
Paste
Alignment
Bridging
Volume
Site Limit Set Options

INFINIT
Y
',163(&7,21
',163(&7,216(783
8.24 User Manual Software Version 7
4. Enter limit set options using Next, Previous, Incr. and Decr. keys.
5. Select Exit.
6. Select Save Limits. The message ‘Saving Fiducial Data - Please Wait
Board data file saved’ is displayed.
7. Select Exit.
8. Select Exit.
Selecting an
Existing Site
To edit an existing site carry out one of the following procedures:
• Using the mouse left button or touchscreen (if available) select the position
of the site on the representation of the board.
• Using the mouse left button or touchscreen (if available) select the site (or
device) name on the devices and site list.
• Use the Next / Previous buttons on the menu bar.
When an existing site is selected the following GUI display information is
updated:
• Site parameter information.
• Site X and Y coordinates.
• Vision panel camera display image of new site.
Next Previous Incr. Decr. Exit
Next Previous Incr. Decr. Exit
Limit
Options
Save
Limits
Next Previous Incr. Decr. Exit
Limit
Options
Save
Limits
Next Previous Incr. Decr. Exit
Add
Limits
Edit
Limits
Next
Limit
Previous
Limit
Exit