DEK INFINITY USER MANUAL - 第281页
INFINITY ',163(& 7,21 0(18 3$5$ 0(7 (56 Soft ware Ver sion 7 User Manual 8.41 Paste Scaling This parame ter enables adjustme nt of the past e scaling value for the current site, to cause the value of paste pr…

INFINIT
Y
',163(&7,21
0(183$5$0(7(56
8.40 User Manual Software Version 7
Smear Clean This parameter sets the type of screen clean performed on a smear alarm. The
options are:
Low Paste Action This parameter sets the action performed on a low paste alarm. The options are:
Inspect After Clean This parameter sets whether the stencil is inspected before the next board is
printed following a screen clean. The options are:
No. Sites This parameter displays the total number of sites.
Site Name The unique name given to a site for identification. The name can have a
maximum of 20 characters.
Site Priority This parameter determines the priority of a site. Where the site is part of a
device, the value applies to the whole device. The options are:
NOTE
If the machine inspection page is set to GUI 2Di, all displayed sites are coloured
coded, depending on their priority setting, (following table refers):
Site Alignment This parameter sets what alignment data is reported for each site. The options
are:
Limit Set ID The unique name given to a set of limits which can be applied to any site. This
enables different sites to be inspected according to different limits. The name
can have a maximum of 20 characters. A maximum of 14 limit sets can be
created.
Mode 1 Mode 2
Manual Re-print
Disabled Enabled
Minimum Maximum Increments
010001
Not Inspected General Every Cycle
Site Priority Display Colour
Every Cycle
Green
General
Yellow
Not Inspected
Blue
X & Y X Only Y Only None

INFINITY
',163(&7,21
0(183$5$0(7(56
Software Version 7 User Manual 8.41
Paste Scaling This parameter enables adjustment of the paste scaling value for the current site,
to cause the value of paste present on the pad, currently selected in the inspection
list, to be reported as 100%. This parameter is used in conjunction with the Auto
Scale function.
Site X Coord The coordinate of a site taken from the front left corner of the board, in the X
direction.
Site Y Coord The coordinate of a site taken from the front left corner of the board, in the Y
direction.
Site Width The width of the site to be inspected.
Site Height The height of the site to be inspected
Blockage Warning This parameter sets the amount of aperture blockage required to initiate a
warning.
Blockage Alarm This parameter sets the amount of aperture blockage required to initiate an
alarm.
Smear Warning This parameter sets the amount of stencil smear required to initiate a warning.
Minimum Maximum Increments
0.01 2.00 0.01
Minimum Maximum Increments
0.0mm Board Length 0.1mm
Minimum Maximum Increments
0.0mm Board Width 0.1mm
Minimum Maximum Increments
0.5mm 4.0mm 0.01mm
Minimum Maximum Increments
0.5mm 6.5mm 0.01mm
Minimum Maximum Increments
0% 100% 1%
Minimum Maximum Increments
0% 100% 1%
Minimum Maximum Increments
0.01 sq. mm 10 sq. mm 0.01 sq. mm

INFINIT
Y
',163(&7,21
0(183$5$0(7(56
8.42 User Manual Software Version 7
Smear Alarm This parameter sets the amount of stencil smear required to initiate an alarm.
Paste Warning This parameter sets the amount of paste on pad required to initiate a warning.
Paste Alarm This parameter sets the amount of paste on pad required to initiate an alarm.
Align Warning This parameter sets the amount of X or Y alignment error of the paste to initiate
a warning.
Align Alarm This parameter sets the amount of X or Y alignment error of the paste to initiate
an alarm.
Bridge Warning This parameter sets the distance between adjacent deposits of paste that if not
exceeded initiates a warning.
Bridge Alarm This parameter sets the distance between adjacent deposits of paste that if not
exceeded initiates an alarm.
Volume Warning This parameter sets the volume of paste on pad required to initiate a warning.
Minimum Maximum Increments
0.01 sq. mm 10 sq. mm 0.01 sq. mm
Minimum Maximum Increments
0% 100% 1%
Minimum Maximum Increments
0% 100% 1%
Minimum Maximum Increments
0.005mm 0.25mm 0.001mm
Minimum Maximum Increments
0.005mm 0.25mm 0.001mm
Minimum Maximum Increments
0.01mm 0.5mm 0.005mm
Minimum Maximum Increments
0.01mm 0.5mm 0.005mm
Minimum Maximum Increments
0% 100% 1%