DEK INFINITY USER MANUAL - 第314页

INFINITY &21680$ %/(5(3/ (1,6+0(1 76 9257(;81' (56&5 ((1&/($ 1(5 9.30 User Manual Software Versi on 7 Solvent Advice The following solvents MUST NOT be used in the underscreen cleaner . How- ever , th…

100%1 / 356
INFINITY
&21680$%/(5(3/(1,6+0(176
9257(;81'(56&5((1&/($1(5
Software Version 7 User Manual 9.29
Vortex Cassette Life This parameter sets the number of cleaning strokes that are applied before a
cleaning cassette is replaced.
Vortex Clean Rate This parameter sets the frequency (in print cycles) at which screen cleaning
occurs.
Vortex Solvent Rate This parameter sets the frequency (in cleaning cycles) at which solvent is
dispensed.
Vortex Vacuum Start The distance, in from the front edge of the board, where vacuum is applied.
Vortex Vacuum Stop The distance, in from the front edge of the board, where vacuum application is
stopped.
Vortex Vacuum Rate This parameter sets the frequency (in cleaning cycles) at which vacuum is
applied.
Vortex Vacuum
Period
This parameter sets the period for which vacuum is applied.
Dry Clean Speed This parameter sets the speed of the screen clean return stroke.
Minimum Maximum Increment Default
02001 20
Minimum Maximum Increment Default
02001 0
Minimum Maximum Increment Default
1101 1
Minimum Maximum Increment Default
Vacuum Stop Board Width 1mm 0mm
Minimum Maximum Increment Default
-100mm Vacuum Stop 1mm 0mm
Minimum Maximum Increment Default
1101 1
Minimum Maximum Increment Default
1 sec 10 secs 1 sec 5 secs
Minimum Maximum Increment Default
10mm/sec 120mm/sec 1mm/sec 30mm/sec
INFINITY
&21680$%/(5(3/(1,6+0(176
9257(;81'(56&5((1&/($1(5
9.30 User Manual Software Version 7
Solvent Advice The following solvents MUST NOT be used in the underscreen cleaner. How-
ever, this list is not complete and does not mean that any solvent not mentioned
is compatible, with DEK machines.
Rosstech 106 FE
Rosstech 162 ND
Acetone
DEK are continuously evaluating alternative solvents. If you wish to use a
particular type of solvent, but are unsure of its suitability for DEK machines,
please contact the DEK Customer Support Group.
1. Press Setup (F6).
2. Press Edit Data (F3).
The following window is displayed:
3. Use the Next and Previous keys (F4 - F5) to highlight the required parame-
ter.
4. Use the Incr. and Decr. keys (F6 -F7) to set the required value of the selected
parameter.
5. Repeat Steps 3 and 4 for all remaining parameters.
Run Head
Paste
Load
Clean
Screen
Adjust Setup Monitor Maint.
Mode
Load
Data
Edit
Data
Setup
Squeegee
Change
Screen
Change
Tooling
Change
Language
Exit
UNDER CLEARANCE
SEPARATION SPEED
SEPARATION DISTANCE
BOARD COUNT
PRINT DEPOSITS
PASTE WHILE CLEAN
PASTE RIDGE REMOVAL
VORTEX CLEAN RATE
VORTEX SOLVENT RATE
VORTEX VACUUM START
VORTEX VACUUM STOP
VORTEX VACUUM RATE
VORTEX VACUUM PERIOD
DRY CLEAN SPEED
19.0
2
3.0
0
1
Disabled
Enabled
0
1
Board Width
0
1
5
40
mm
mm/s
mm
boards
Print Cycle
Clean Cycle
mm
mm
Clean Cycle
Second
mm/s
.. more
Edit Current Process Parameters
Save Next Previous Incr. Decr. Exit
Save Next Previous Incr. Decr. Exit
INFINITY
&21680$%/(5(3/(1,6+0(176
9257(;81'(56&5((1&/($1(5
Software Version 7 User Manual 9.31
6. Press Save (F2) on completion of parameter setup.
7. Press Exit (F8).
8. Press Exit (F8).
Cleaning Cassette
and Solvent
Replenishment
The cleaning cassette and solvent replenishment can take place with the cleaner
unit in the printer. When the cleaning cassette or solvent needs replenishment a
warning window is automatically displayed on the monitor. The warning
window varies, depending on the setting of the consumable action option in set
preferences. The message in the warning window depends on whether the
cleaning cassette or solvent or both require replenishment. The procedure
varies, depending on whether the replenishment is prior to a print run or during
a print run.
Replenishment Prior to a Print Run:
If the set preference is set to warn, continue with Step 1. If the set preference is
set to pause or suspend go to Step 4.
1. If the set preference is set to warn, the tricoloured beacon shows amber/green
and the following window is displayed:
2. Select Confirm (F1).
3. Go to Step 17.
Save Next Previous Incr. Decr. Exit
Save Next Previous Incr. Decr. Exit
Mode
Load
Data
Edit
Data
Setup
Squeegee
Change
Screen
Change
Tooling
Change
Language
Exit
Warning
Vortex cleaning cassette expired. Please replace.
Confirm