INFINITY &21680$ %/(5(3/ (1,6+0(1 76 9257(;81' (56&5 ((1&/($ 1(5 9.36 User Manual Software Versi on 7 2. Dispose of the used cleaning cassette in accordance with local authority guidel ines. 3. If the…

100%1 / 356
INFINITY
&21680$%/(5(3/(1,6+0(176
9257(;81'(56&5((1&/($1(5
Software Version 7 User Manual 9.35
4. Prime the solvent using the two button control.
5. Press Lower Head (F2).
6. Remove the head prop.
7. Select Confirm (F1).
8. Lower the printhead using two button control.
9. Close the front printhead cover.
10.Press the System button.
Cleaning Cassette Replenishment
WARNING
PROTECTIVE CLOTHING. APPROVED PROTECTIVE CLOTHING SHOULD BE
WORN BY SOLDER PASTE AND SOLVENT HANDLERS AT ALL TIMES TO
ELIMINATE FUME INHALATION, EYE CONTACT, SKIN CONTACT AND
INGESTION.
WARNING
FLAMMABLE. THE USED VORTEX CLEANING CASSETTE AND VORTEX FILTER
CASSETTE CONTAIN RESIDUES OF UNDERSCREEN CLEANER FLUID AND
SOLDER PASTE. OBSERVE MANUFACTURERS RECOMMENDED DISPOSAL
INSTRUCTIONS.
NOTE
The cleaning cassettes come in different sizes, ensure the correct size is replaced.
1. Carefully lift the cleaning cassette (1) clear of the two pip pins (2) and slide
out from beneath the solvent bar (3).
Lower
Head
Board
Clamps
Prime
Paper
Prime
Solvent
Exit
Confirm Cancel
1
2
2
3
INFINITY
&21680$%/(5(3/(1,6+0(176
9257(;81'(56&5((1&/($1(5
9.36 User Manual Software Version 7
2. Dispose of the used cleaning cassette in accordance with local authority
guidelines.
3. If the filter cassette is to be replaced continue with Step 4. If the filter
cassette is not being replaced go to Step 7.
NOTE
The filter cassettes are available in varying sizes, ensure the correct size is
replaced.
4. Remove the vacuum grid (1) from the mounting tray (3). Remove the filter
cassette (2) from the mounting tray (3).
5. Dispose of the used filter cassette in accordance with local authority guide-
lines.
6. Fit the new filter cassette (2) into the mounting tray (3). Fit the vacuum grid
(1) into the mounting tray (3).
1
2
3
1
2
3
INFINITY
&21680$%/(5(3/(1,6+0(176
9257(;81'(56&5((1&/($1(5
Software Version 7 User Manual 9.37
7. Fit the edge of the new cleaning cassette (1) beneath the solvent bar (3) and
snap into place on the two pip pins (2).
8. Press Prime Solvent (F6) key. The message Press the two button control
buttons to prime solvent. is displayed.
9. Prime the solvent using the two button control.
10.Remove the head prop.
11. Select Confirm (F1).
12.Lower the printhead using two button control.
13.Close the front printhead cover.
14.Press the System button.
1
2
2
3
Lower
Head
Board
Clamps
Prime
Solvent
Exit
Confirm