INFINITY 0$&+,1( 352*5$ 00,1* 67$*( 35,17,1 58102' ( 1.88 User Manual Software Versi on 7 The machine continues to run using the existing values, when Exit (F8) is select ed the ne w valu es are use d.…

100%1 / 356
INFINITY
0$&+,1(352*5$00,1*
67$*(35,17,158102'(
Software Version 7 User Manual 1.87
9. Repeat Steps 7 and 8 for the other deflector.
10.Close the front printhead cover.
11. Press the System button.
12.Select Continue (F1).
13.After the squeegee has moved approximately 20mm, select Stop Cycle (F2).
14.Open the front printhead cover.
15.Check the deflectors are not touching the screen.
16.Close the front printhead cover.
17.Press the System button.
18.Select Continue (F1).
19.Repeat Steps 5-18 for the other squeegee.
20.The printer operates continuously. The menu bar displays the following
options, these may be selected at any time during a print run:
End Run Selecting this option stops the printer on completion of the current print cycle.
Stop Cycle Selecting this option stops the printer immediately, halting all actions.
Paste Load Selecting this option allows the operator to load paste to the screen either
manually or automatically.
Clean Screen Selecting this option allows the operator to clean the screen in addition to the
programmed cleaning intervals.
Adjust Selecting this option allows the operator to adjust any of the main process
parameters displayed on the pop-up menu without having to access the main
menu or stop the machine.
Continue
End
Run
Stop
Cycle
Paste
Load
Clean
Screen
Adjust
Knead
Paste
Adjust
Inspect
Continue
End
Run
Stop
Cycle
Paste
Load
Clean
Screen
Adjust
Knead
Paste
Adjust
Inspect
INFINITY
0$&+,1(352*5$00,1*
67$*(35,17,158102'(
1.88 User Manual Software Version 7
The machine continues to run using the existing values, when Exit (F8) is
selected the new values are used.
To save the new values, select Setup (F6), select Edit Data (F3), select Save
(F2), select Exit (F8).
Knead Paste Selecting this option runs the knead paste process in addition to the programmed
cleaning intervals.
Adjust Inspect Selecting this option allows the operator to edit 2D inspection parameters.
NOTE
Global Limits, Limit Sets and Site parameters can be edited. Site Co-ordinates
can not be adjusted. Any changes made to inspection parameters are saved on
exit.
INFINITY
0$&+,1(352*5$00,1*
0(183$5$0(7(56
Software Version 7 User Manual 1.89
MENU PARAMETERS
Each product has a set of parameters which are unique to that particular product
and which need to be setup to obtain acceptable printing results. These parame-
ters are listed below with a definition of each as an aid to machine setup.
Product Name The file name for the particular product. The name can consist of up to eight
alphanumeric characters with no punctuation.
Product ID The product ID is a parameter that allows a description of the product. This
string may be up to 32 characters long, but only the first 20 characters are
displayed.
Product Barcode The barcode number for the particular product. The barcode can be up to twenty
characters long. This parameter is only used if the machine if fitted with a
product barcode reader.
Screen Barcode The barcode number that identifies the particular screen to be used with this
particular product. The barcode can be up to twenty characters long. If the screen
has a barcode printed on it in the correct place and the machine is initialized to
read the code, the screen is checked to ensure it is correct after it has been fitted.
If it is incorrect a message is displayed on the monitor. This parameter is only
used if the machine is fitted with a product barcode reader.
Dwell Height The parameter allows the user to set the squeegee dwell height. Setting of a
lower height helps the media to stay evenly spread across the length of the
squeegee when a less viscous media is used. Setting a high height allows
viewing of the paste roll.
Dwell Speed This preference adjusts the speed at which the squeegee moves to dwell height.
A slower speed helps to reduce the spreading of a less viscous media, ie flux. It
should be noted that decreasing this speed causes the cycle time to increase.
Image Detail This parameter allows the user to modify the screen image data of the selected
screen library file. Once selected, pressing Incr. or Decr. Keys opens the Image
Detail Configuration page.
NOTE
This parameter is only displayed, if Screen Size in Set Preferences has been
selected to Screen Library.
Minimum Maximum Increment Default
5.0mm 40.0mm 1.0mm 30.0mm
Minimum Maximum Increment Default
10.0mm/sec 30.0mm/sec 1.0mm/sec 24.0mm/sec