222085 Issue 1 - Horizon APiX Appendix Manual - 第104页
TECHNICAL REFERENCE APPENDIX PREVENTIVE MAINTENANCE Chapter Issue 1 June 15 Appendix to Micron Technical Manuals 3.67 SEMI Level PC Enclosure Tick Inspect wiring and connections. SEM I 1 Estimated time req uired for Mont…

TECHNICAL REFERENCE APPENDIX
PREVENTIVE MAINTENANCE
3.66 Appendix to Micron Technical Manuals Chapter Issue 1 June 15
Monthly Hardware Check
SEMI Level Machine Safety Tick
The Factory supply must be isolated and locked out before an examination of the
mains input lead can be carried out.
Examine the condition of the mains input lead.
Check all earth leads and bonding points are connected.
Check operation of the cover interlock.
Check operation of the Emergency Machine Off button.
Toggle all beacon lights.
SEMI 1
SEMI 2
SEMI Level Pneumatics Tick
Check air pressure switch is set to 3 bar.
Check the air inlet regulator is set to 4.5 bar.
Check pipes for air leaks.
Check and empty the air line water trap.
SEMI 1
SEMI Level M36 Control Enclosure Tick
Inspect wiring and connections.
Ensure cards are seated properly.
Clean area around air inlets.
SEMI 1
SEMI Level M37 Power Supply Enclosure Tick
Inspect wiring and connections.
Clean area around air inlet.
SEMI 1
SEMI Level M39 Emergency Machine Off Enclosure Tick
Inspect wiring and connections.
SEMI 1

TECHNICAL REFERENCE APPENDIX
PREVENTIVE MAINTENANCE
Chapter Issue 1 June 15 Appendix to Micron Technical Manuals 3.67
SEMI Level PC Enclosure Tick
Inspect wiring and connections.
SEMI 1
Estimated time required for Monthly tasks 4.0 hours
Summary/Remarks
Signed: Date:

TECHNICAL REFERENCE APPENDIX
PREVENTIVE MAINTENANCE
3.68 Appendix to Micron Technical Manuals Chapter Issue 1 June 15
Month February Maintenance Procedure
WARNING
BOARD CLAMPS. EXTREME CARE MUST BE EXERCISED WHEN WORKING IN
THE TOOLING AREA OF THE MACHINE TO AVOID INJURY. THE FOILS ON THE
FRONT AND REAR BOARD CLAMPS ARE VERY SHARP.
WARNING
HARMFUL SUBSTANCES. CLEANING WIPES AND CLEANING SOLUTIONS MAY
CONTAIN SUBSTANCES HAZARDOUS TO HEALTH. OBSERVE ALL
MANUFACTURERS’ HEALTH AND SAFETY GUIDELINES. ALWAYS WEAR
APPROVED PROTECTIVE CLOTHING WHEN CLEANING THE MACHINE.
SPC Alignment
Check and Machine
Cycle Count
Fill out details: SPC Alignment Check and Machine Cycle Count at the start of
this section.
Software
Monthly Maintenance
SEMI Level Software Check Record Tick
Check the date and time settings.
Check the software loaded and options.
Check the software version is the latest issue.
SEMI 2
SEMI Level View Event Log Tick
Check for initialisation errors.
Check for screen position errors (31210, 31211, 31212).
Check for camera errors (31207, 31208).
SEMI 2
SEMI Level Under Screen Cleaner (USC) Tick
Check the condition of the squeegee blades (Blue).
NOTE
ASM recommend squeegee blades are replaced every six months.
Check the screen cleaner height.
Check the condition of all hoses and connections.
SEMI 1