EMERGENCY MACHINE OFF (EMO) OPERATION
With the machine powered up, activating the red Emergency Machine Off
button (EMO) immediately powers down the machine both electrically and
pneumatically.
If the EMO is operated during machine movement, electrical and pneumatic
power is immediately removed. Machine movement may continue under inertia
and may result in machine damage. To avoid machine damage, ensure the
machine is shutdown correctly by following the Power Down procedure in the
Operator manual.
NOTE
The EMO is a safety feature intended to power down the equipment in an
emergency so as to protect personnel and equipment. In case of an emer-
gency, it may not be possible to access the main disconnect device on the
equipment leaving the EMO as the only means to power down the equipment.
This is a requirement of SEMI S2.
To activate:
Press the EMO button, electrical and
pneumatic power to the machine is
removed.
To reset:
Turn the EMO button clockwise to release
the latch.
Press the Start button (green) to restore
electrical and pneumatic power.
OPERATOR APPENDIX
PRINTHEAD COVER
1.2 Appendix to Micron Technical Manuals Chapter Issue 1 June 15
PRINTHEAD COVER
Raising the printhead cover suspends operation of the machine to allow the
operator safe access to the tooling area.
Safety Devices The safety devices designed into this machine are for the protection of all
operator and maintenance personnel. ASM strongly recommend safety
devices are never overridden.
OPERATOR APPENDIX
TRI COLOUR BEACON
Chapter Issue 1 June 15 Appendix to Micron Technical Manuals 1.3
TRI COLOUR BEACON
The beacon indicates the operational status of the machine:
Beacon Colour Operational Status
Machine is not operational
System power is down
Error message displayed
Paste cartridge is low
Paper roll is empty
Solvent tank level is low
Machine is not in a ready state
Machine is initialising
Machine is in set up mode
Machine is in maintenance mode
Machine requires operator attention
Paste cartridge is low
Paper roll is low
Solvent tank level is low
Machine is operational
Machine is waiting in a ready state