222085 Issue 1 - Horizon APiX Appendix Manual - 第40页

TECHNICAL REFERENCE APPENDIX ELECTRICAL SCHEMATIC Chapter Issue 1 June 15 Appendix to Micron Technical Manuals 3.3 ELECTRICAL SCHEMA TIC N N E E Mains Isolator TB1 TB2 TB3 TB8 L L TB4 TB5 TB7 8A EMO Safe PSU M39 Emergenc…

100%1 / 166
TECHNICAL REFERENCE APPENDIX
EMERGENCY MACHINE OFF MODULE
3.2 Appendix to Micron Technical Manuals Chapter Issue 1 June 15
WARNING
LETHAL VOLTAGE. DANGEROUS VOLTAGES EXIST IN THIS EQUIPMENT.
ENSURE ALL ELECTRONIC COVERS AND MAIN MACHINE COVERS ARE
FITTED BEFORE OPERATING THIS EQUIPMENT.
Mains input power (115V to 230V) to the machine is routed to the mains isolator
switch at the front of the machine. From the mains isolator it is fed to the M39
emergency machine off enclosure, through one of the cable glands at the rear
panel, to the three terminal blocks TB1 (live), TB2 (neutral) and TB3 (earth).
From the terminal blocks mains power is supplied to the EMO Safe Power
Supply Unit (EMO PSU) and to M37 power supply crate via the closed contacts
of contactors CON1 and CON2.
The EMO PSU supplies +24V dc to terminal block TB4. From TB4 the +24V dc
is distributed to the E-Stop relay RL 1 and the pneumatic dump valve 16SOL37
through the closed contacts of CON1 and CON2.
The front and rear EMO push button switches are connected in series across
relay RL1. If either switch is operated the mains power supply to the M37 power
supply crate is immediately removed. The pneumatic air pressure supply to the
machine is also removed and any remaining pneumatic pressure within the
machine is vented safely to atmosphere.
The front panel connector (M39SK5) is provided for maintenance purposes to
apply a +24V dc supply to the EMO enclosure for electrical testing.
NOTE
Following a service visit that involves any disturbance of components in the
mains voltage circuit an electrical test as detailed in the Pre Power section of
the Transportation chapter must be undertaken. Before testing ensure that the
machine is isolated from the factory supply and that any external equipment (ie
upline and downline conveyors) are disconnected.
TECHNICAL REFERENCE APPENDIX
ELECTRICAL SCHEMATIC
Chapter Issue 1 June 15 Appendix to Micron Technical Manuals 3.3
ELECTRICAL SCHEMATIC
N
N
E
E
Mains
Isolator
TB1
TB2
TB3
TB8
L
L
TB4
TB5
TB7
8A
EMO Safe PSU
M39 Emergency Machine Off Enclosure
PSU 1
L
+24V
0V
N
E
TB6
8A
CON1
CON2
RL1
E-Stop
Relay
M39PL1
1
2
3
4
5
6
M39PL3
M39SK5
M39PL4
16SK37
Start Button
14SW4
Pneumatic Dump
16SOL37
1
1
1
1
+ve
-ve
2
2
2
2
3
3
4
4
Front Panel
M39PL2
1
2
3
4
5
6
E
To M37 Power
Supply Crate
For Electrical
Testing
8SK/PL64
1
2
3
4
5
6
Front EMO Actuator
8ES5
Rear EMO Actuator
8ES5
TECHNICAL REFERENCE APPENDIX
M39 EMERGENCY MACHINE OFF ENCLOSURE
3.4 Appendix to Micron Technical Manuals Chapter Issue 1 June 15
M39 EMERGENCY MACHINE OFF ENCLOSURE
Figure 3-1 M39 Emergency Machine Off Enclosure - Plan View
Item Description Item Description
1 Mains Power Input & Output Glands 9 Terminal Block TB2
2 EMO Safe Power Supply Unit PSU 1 10 Terminal Block TB1
3 Contactor CON1 11 Socket M39SK05
4 Contactor CON2 12 Terminal Block TB6
5 E-Stop Relay RL1 13 Terminal Block TB7
6 Terminal Block TB5 14 Sockets M39SK2 & 4
7 Terminal Block TB4 15 Sockets M39SK1 & 3
8 Terminal Block TB3
1
2
56789
10
11
12
13
14
15
4 3