00196577-03 JG S-Feeder Care Test Station EN - 第32页
Performing the Test – Results Display: Details 32 – R e s u lt s D is p la y : D e t a ils The R e s u lt D i s p la y D e t ai ls T r a c k L / M / R shows the meas - uring result for each individual t rack in the X an …

Performing the Test – Results Display
31
– Results Display
The results of the Test Feeder function will be shown in the
Result Display.
Each tested track will be shown separately.
Click on OK to close the dialog box and to automatically
eject the tape.
Click on Details to view the detailed test results for an indi-
vidual track.
Click on the Protocol… button to view the whole test result
as a PDF file which can then be saved and/or printed out.
To make sure that you are able to clearly identify or assign
the PDF file later on, enter the serial number of the tested
feeder in a dialog box before saving or printing.

Performing the Test – Results Display: Details
32
– Results Display: Details
The Result Display Details Track L / M / R shows the meas-
uring result for each individual track in the X and Y directions
as a graphic. The upper part of the displayed graphic shows
the position of the individual teeth in the direction of feeding
while the lower part shows the individual teeth across the di-
rection of feeding.

Performing the Test – Results Display: Details
33
There are two tolerance areas:
1. The two orange lines mark the limits of the tolerance area.
These lines have a fixed position. The lines correspond to
the orange rectangle in the camera image.
2. The two blue lines mark the limits of the worm gear play.
These lines can be shifted according to the average value
of the measurements.
The green dots show the measuring results which are inside
the two tolerance areas.
The red dots show measuring values which are outside at
least one of the tolerance areas.
Red squares show positions at which measurement failed.
Click on OK to close the dialog box and view the results dis-