00196577-03 JG S-Feeder Care Test Station EN - 第48页
Performing the Test – Test with feeder feducial (for 2x8mm S Fe eder only) 48

Performing the Test – Test with feeder feducial (for 2x8mm S Feeder only)
47
NOTICE
Position of sprocket wheel
The absolute position of the sprocket wheel will then be measured against the feeder adapter. This might cause
an additional offset (up to 100µm in transport direction and up to 200µm across transport direction), so that the
measurement can exceed the tolerance corner (see chapter 5.2.3.1 "measurement result out of tolerance). Some
of dots are then outside the orange lines.
The feeder however might still be suitable to use (e.g. for chips >= 0805), as long as the repeatability is still good
(measurements are within the blue tolerance lines).

Performing the Test – Test with feeder feducial (for 2x8mm S Feeder only)
48

Performing the Test – Test with feeder feducial (for 2x8mm S Feeder only)
49
NOTICE
Measuring without checking the feeder feducial
Feeder which has been tested this way should be marked respectively.
The checking of the feeder feducial can be deactivate for 2x8mm S-Feeder only.
The following warning will be shown on the display and in the protocol.
WARNING
Feducial recognition deactivated
Checking is performed without feducial recognition.
This function is available for 2x8mm S-Feeder only. In case the feducial cannot be identified by the position recog-
nition the feducial regognition can be deactivated. These feeder must not be used at the station using the feeder
recognition function.