00196622-03_OM_WPC5_6_EN - 第25页
Module Technical Data Overview of WPC5/WPC6 Operating Manual SIPLACE WPC5/WPC 6 25 3 3 M o d u le T e c h n ic a l D a t a Module Technical Data The Technical data of WPC5 and WPC6 are basically identical. An y differenc…
Operational Safety
ESD Guidelines 2.5.3 Dispatching ESD Modules
24 Operating Manual SIPLACE WPC5/WPC6

Module Technical Data
Overview of WPC5/WPC6
Operating Manual SIPLACE WPC5/WPC6 25
3
3 Module Technical Data
Module Technical Data
The Technical data of WPC5 and WPC6 are basically identical. Any differences are explicitly pointed out.
3.1
3.1 Overview of WPC5/WPC6
Overview of WPC5/WPC6
3.2
3.2 Overview of the Modules
Overview of the Modules
1. SIPLACE SX1/SX2
2. WPC6
3. Non-Stop Module (only WPC6)
4. Changeover table with 30 tracks
1. Protective door
2. Non-Stop Module (only WPC6)
3. EMERGENCY STOP button
4. Main switch
5. Protective covers on the power supply
6. Crank handle for lifting or lowering the trolley carriage
7. Protective covers on the lifting mechanism (tower)
8. Feed axis with waffle pack tray carrier
9. Cover over the feed axis drive

Module Technical Data
Connection Values 3.3.1 Electrical Connections
26 Operating Manual SIPLACE WPC5/WPC6
3.3
3.3 Connection Values
Connection Values
3.3.1
3.3.1 Electrical Connections
Electrical Connections
3.3.2
3.3.2 Environmental Conditions for Operation
Environmental Conditions for Operation
3.3.3
3.3.3 Pneumatic Connections and Compressed Air Specifications
Pneumatic Connections and Compressed Air Specifications
Supply voltage 3 x 208 V~ ± 10 %; 50/60 Hz (U.S.A)
3 x 230 V~ ± 10 %; 50/60 Hz
3 x 380 V~ ± 10 %; 50/60 Hz
3 x 400 V~ ± 10 %; 50/60 Hz (Europe)
3 x 415 V~ ± 10 %; 50/60 Hz
Nominal apparent power 1.5 kVA
Nominal active power 1.0 kW
Fuse rating 3 x 10 or 3 x 16 A
Room temperature between 15°C and 35°C
Humidity 30% to 75%(but no higher than 45% on average in
order to prevent any possibility of condensation on
the machine).
Air connection, vacuum connection Not applicable