00193351-06_RI_Vacuum_pump_de en - 第35页

SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF -Series 2 Retrofit instructions for vacuum pump 07/2011 Edition 33 : Open the two middle screws of the trailing cable. 2 2 : Remove the cover of th e gantry distributor (3 scr ews)…

100%1 / 60
2 Retrofit instructions for vacuum pump SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series
07/2011 Edition
32
: Screw the compressed air unit / vacuum block into the machine.
2
2
Changes at the gantry 2
: Remove the component reject bin.
2
2
2
2
2
2
2
2
Vacuum distributor
with 8 vacuum
hoses
A new compresseed air
hose and a blind plug
per stopcock
SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series 2 Retrofit instructions for vacuum pump
07/2011 Edition
33
: Open the two middle screws of the trailing cable.
2
2
: Remove the cover of the gantry distributor (3 screws).
2
2
2
2
2
2
2 Retrofit instructions for vacuum pump SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series
07/2011 Edition
34
2.3.4 SIPLACE HS-50
: Insert the newly installed PUN8-hose in the adapter PUN8 / PUN4.
2
2
: Loosen the vacuum hose PUN4 of the gantry distributor block and insert the hose in the adap-
ter PUN8/PUN4.
: Install the cover of the trailing cable.
: Install the gantry cover and the rejection bin.
2
Changes on the placement head 2
: Remove the head board.
: Remove the hoses from the vacuum generator.
: Remove the vacuum generator.
: Install the vacuum generator for the vacuum pump (item no. 00307848-01).
: Connect the hoses to the new vacuum generator.
: Remove the Y-joint of hoses no. 5 and no. 2.
PUN8/PUN4
adapter
Newly installed
compressed air hose
Vacuum hoses
Gantry distributor block