00193351-06_RI_Vacuum_pump_de en - 第37页

SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF -Series 2 Retrofit instructions for vacuum pump 07/2011 Edition 35 : Use hose n o.1 for compr essed air . The remaining hose s are for vacuum. : Mount the head boar d. 2 2 2 2 2 2 …

100%1 / 60
2 Retrofit instructions for vacuum pump SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series
07/2011 Edition
34
2.3.4 SIPLACE HS-50
: Insert the newly installed PUN8-hose in the adapter PUN8 / PUN4.
2
2
: Loosen the vacuum hose PUN4 of the gantry distributor block and insert the hose in the adap-
ter PUN8/PUN4.
: Install the cover of the trailing cable.
: Install the gantry cover and the rejection bin.
2
Changes on the placement head 2
: Remove the head board.
: Remove the hoses from the vacuum generator.
: Remove the vacuum generator.
: Install the vacuum generator for the vacuum pump (item no. 00307848-01).
: Connect the hoses to the new vacuum generator.
: Remove the Y-joint of hoses no. 5 and no. 2.
PUN8/PUN4
adapter
Newly installed
compressed air hose
Vacuum hoses
Gantry distributor block
SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series 2 Retrofit instructions for vacuum pump
07/2011 Edition
35
: Use hose no.1 for compressed air.
The remaining hoses are for vacuum.
: Mount the head board.
2
2
2
2
2
2
New vacuum generator
1x compressed air
6x vacuum
hoses
2 Retrofit instructions for vacuum pump SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series
07/2011 Edition
36
2.3.4.1 SIPLACE HS-60/D4
: Plug the new PUN8 hose into the reducing adapter PUN8 / PUN4.
: Loosen the compressed air hoses 6 and 7 (PUN4) from the gantry distributor block and plug
them into the reducing adapter.
: Plug hose 1 as shown in the picture below.
2
Don’t use the black blind plug of the former assignment for the modification vacuum pump.
Use the silver one! 2
2
2
Assignment at serial machine 2
Assignment vacuum pump 2
No. 1
No. 2
No. 3
No. 4
No. 7
No. 6
No. 5
No. 2
No. 3
No. 4
No. 1
No. 5
No blind plugs necessary,
because there is no connec-
tion to the other assignments