00193351-06_RI_Vacuum_pump_de en - 第38页

2 Retrofit instructions for vacuum pump SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series 07/2011 Edition 36 2.3.4.1 SIPLACE HS-60/D4 : Plug the new PUN8 hose into the red ucing adapter PUN8 / PUN4. : Loosen the compresse d…

100%1 / 60
SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series 2 Retrofit instructions for vacuum pump
07/2011 Edition
35
: Use hose no.1 for compressed air.
The remaining hoses are for vacuum.
: Mount the head board.
2
2
2
2
2
2
New vacuum generator
1x compressed air
6x vacuum
hoses
2 Retrofit instructions for vacuum pump SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series
07/2011 Edition
36
2.3.4.1 SIPLACE HS-60/D4
: Plug the new PUN8 hose into the reducing adapter PUN8 / PUN4.
: Loosen the compressed air hoses 6 and 7 (PUN4) from the gantry distributor block and plug
them into the reducing adapter.
: Plug hose 1 as shown in the picture below.
2
Don’t use the black blind plug of the former assignment for the modification vacuum pump.
Use the silver one! 2
2
2
Assignment at serial machine 2
Assignment vacuum pump 2
No. 1
No. 2
No. 3
No. 4
No. 7
No. 6
No. 5
No. 2
No. 3
No. 4
No. 1
No. 5
No blind plugs necessary,
because there is no connec-
tion to the other assignments
SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series 2 Retrofit instructions for vacuum pump
07/2011 Edition
37
2
: Fix the cable trailing plate on the machine frame.
: Mount the cover plate of the gantry and the component reject bin.
2
Changes on the placement head 2
: Remove the hoses from the vacuum generator.
: Remove the vacuum generator.
: Install the vacuum generator for the vacuum pump.
: Connect the hoses to the new vacuum generator.
2
Vacuum circuit
Compressed air
circuit
Airtight cylinder