SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF -Series 2 Retrofit instructions for vacuum pump 07/2011 Edition 41 : Mount the vacuum generato r with the two Allan screws M6. 2 2 : Remount the power supply . 2 1 2 5 3 4 6 (new) …

100%1 / 60
2 Retrofit instructions for vacuum pump SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series
07/2011 Edition
40
: Close the second port in every stopcock with a blind plug.
2
Drilling the necessary holes for vacuum distributor 2
: Pull the power supply out of the placement machine.
: Drill two holes (diameter 4,9 mm), cut two threads M6 into the holes.
2
Vacuum distributor 3/4’
Plug for
vacuum hose
Blind plug
(necessary)
Remove angle shackle
(only S-27 HM))
Compressed air hoses
from stopcocks
40 mm
60 mm
40 mm
SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series 2 Retrofit instructions for vacuum pump
07/2011 Edition
41
: Mount the vacuum generator with the two Allan screws M6.
2
2
: Remount the power supply.
2
1
2
5
3
4
6 (new)
Compressed air distributor
Compressed air distributor
Placement head 1
1
2
New distributor block New distributor block
7
7
Placement head 2
PUN 3 blind plugs
Pneumatics
2 Retrofit instructions for vacuum pump SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series
07/2011 Edition
42
Mount the pneumatic hoses 2
: Loosen the red security screw on the control unit.
2
2
: Unplug the LAN cable.
: Pull the control unit out.
: Lift the control unit and put it to one side to allow the new PUN8 hoses to be pulled through to
the distributor block(s).
2
2
2