00193351-06_RI_Vacuum_pump_de en - 第46页
2 Retrofit instructions for vacuum pump SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series 07/2011 Edition 44 2 2 : Change the vacuum gen erator with the one for vacuum pump. 2 Layout of hoses S-27 HM 2 2 Mind the right layo…

SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series 2 Retrofit instructions for vacuum pump
07/2011 Edition
43
: Plug the LAN cable back in after the new unit has been fitted.
: Loosen the screws.
: Lift the block to a point where the right connection can be achieved.
: Mark the hoses.
: Connect the newly installed PUN 8 hose.
: Reassemble the block.
2
2
2
Distributor block
Screws
Vacuum hoses
Compressed air hose
Vacuum
(existing hoses
Vacuum (existing hoses)
Compressed air
(newly mounted hose)

2 Retrofit instructions for vacuum pump SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series
07/2011 Edition
44
2
2
: Change the vacuum generator with the one for vacuum pump.
2
Layout of hoses S-27 HM 2
2
Mind the right layout of the hoses! 2
2
2
2
Blind plug
Y joint for hoses 1 and 2

SIPLACE HS-50/HS-60/D4/S-25HM/S-27HM/HF-Series 2 Retrofit instructions for vacuum pump
07/2011 Edition
45
: Remove the blind plug and connect the existing compressed air hose.
2
2
Air distributor 2
2
2
: Remove connection 1 and 2.
: Connect plugs 3 and 4 to plugs 1 and 2.
: Connect plugs 5 and 6 to plugs 3 and 4.
: Connect plug 7 to plug 5.
: Connect plugs 1 and 2 to plugs 6 and 7.
Connect compressed air hose