SITEST Calibration Steps and Individual Calibrati on Functions New Functions in SITEST S tuden t Guide Advanced Level 2 SIPLACE D Series SITEST EN 05/2007 12-24 The gantry moves the TWIN module above the compone nt (IC) …

SITEST
New Functions in SITEST Calibration Steps and Individual Calibration Functions
Student Guide Advanced Level 2 SIPLACE D Series
EN 05/2007 SITEST
12-23
Repeat the function for
track 90 (track 72 for D4).
For precision purposes, only
use one 'iron' per location, so
that the feeder pickup
position in the table center is
not affected.
Repeat this function for all
other changeover tables.
Save in REAL.MA.
Calibrating the closed
vacuum
For (head 2 P&P module)
YES
With TWIN
YES In 'P&P module' 'calibrate
head'
The TWIN module picks up
a 518 nozzle from the
nozzle changer.
518 nozzle
The 518 nozzle is moved to
the top edge of the
conveyor side, to measure
the vacuum.
The rubber membrane of the
518 nozzle is sealed onto the
edge of the conveyor side.
The measured vacuum is the
same as the closed vacuum
value for the C&P heads.
Save in --- …. … the closed vacuum is
measured at each reference
run.
Zero adjustment vacuum
For (head 2 P&P module)
YES
With TWIN
YES In 'P&P module' 'head board'
The air blast vacuum is
adjusted to '0'.
The compressed air supply
is disabled.
This is the real '0' state.
The vacuum difference is
measured and after
reactivation, the electronic
control valve is set to the
new 0 value.
The nozzle must not be
manually blocked/closed.
Save in control valve
EPROM
Calibrating the zero point
correction D-axis
For (head 2 P&P module)
YES
With TWIN
YES In 'P&P module' 'calibrate
head'
Replace the current nozzle
on the TWIN module with
the special calibration
nozzle, according to the SW
message.
Calibration step/
individual calibration
function
For D4 For D3 For D2 For D1 Comments

SITEST
Calibration Steps and Individual Calibration Functions New Functions in SITEST
Student Guide Advanced Level 2 SIPLACE D Series
SITEST EN 05/2007
12-24
The gantry moves the TWIN
module above the
component (IC) camera.
Within a +/-5° tolerance, the
SW determines the angle
correction.
Save in Achs_ver.ma.
Calibration menus reserved for SIEMENS Service
FCCS for digital cameras White adjustment of
hardware required.
The PCB camera calibrates
the calibration tool carrier
position after this carrier
has been moved into the
PCB conveyor and clamped
into place.
Other PCB camera test
measurements follow.
All cameras programmed in
the Config.ma file are
brightness calibrated via a
whiteness adjustment
measurement.
Save in camera EPROM! The results can be saved in
the calibration value XML file.
Checking the star mounting
position in the magnetic
neutral position
The star mounting position
is checked by comparing
the magnetic neutral
position with the 'zero
position of segment 1'.
A deviation of up to 95x 1/
1000° is tolerated by the SW.
Should errors occur,
remount the placement star
on the star motor shaft.
Calibration step/
individual calibration
function
For D4 For D3 For D2 For D1 Comments

SITEST
New Functions in SITEST Room for Your Sketches and Notes
Student Guide Advanced Level 2 SIPLACE D Series
EN 05/2007 SITEST
12-25