Communication and Control CAN Bus CAN I/O Module (SLIO) - SIPLACE D4 S tuden t Guide Advanced Level 2 SIPLACE D Series Communication and Control EN 05/2007 4-16 4.3.7 CAN I/O Module (S LIO) - SIPLACE D4 There are 2 CAN B…

Communication and Control
CAN Bus Terminating Resistors CAN Bus
Student Guide Advanced Level 2 SIPLACE D Series
EN 05/2007 Communication and Control
4-15
4.3.6.1 CAN Bus Terminator
The A3 assembly ensures that the CAN bus also functions with undocked changeover tables. During
undocking, a CAN terminating resistor is switched, which maintains the CAN bus function and
communication.
If the terminating resistance is measured with the machine switched off and the changeover tables
connected, you will be able to measure 30 Ohms at the Sub CAN bus (with 500kbit/s). Reason: There
are 4x 120 Ohm resistors switched parallel. When the machine is switched on, the resistors switched in
A3 will be deactivated.
There is an A3 assembly in each sector.
4-12: A3 assembly
*1
D1/D2: WPC and sector 1
*2
D1/D2: Sector 2
S
Feeder table plate
Sector 1
*1
Feeder table plate
Sector 2
*2
Feeder table plate
Sector 3
Feeder table plate
Sector 4
1 ON OFF ON OFF
2ON ON OFF OFF
CAN BUS terminator for changeover table (switch setting S1 on A3 assembly)

Communication and Control
CAN Bus CAN I/O Module (SLIO) - SIPLACE D4
Student Guide Advanced Level 2 SIPLACE D Series
Communication and Control EN 05/2007
4-16
4.3.7 CAN I/O Module (SLIO) - SIPLACE D4
There are 2 CAN Bus I/O modules in the D4 machine. Both modules are absolutely identical and are
located in sectors 2 and 4.
Function
Micro controller with integrated CAN controller
Data memory
Program memory (flash)
CAN interface with 9 pin connector and address alignment
16 digital Output 24 V with status LED
24 digital Input 24 V with status LED
Download interface
Power supply 24 V
Extension on I/O module for the CAN interface (changeover tables)
8 digital inputs can be logically linked with the help of a FPGA (freely programmable gate array). The
FPGA is used for incoming security messages.
4-13: I/O module sector 2
4-14: I/O module sector 4

Communication and Control
CAN I/O Module (SLIO) - SIPLACE D4 CAN Bus
Student Guide Advanced Level 2 SIPLACE D Series
EN 05/2007 Communication and Control
4-17
4-15: Overview CAN I/O module
Legend
DIP Switch on the Main- and Sub Distributor
There is an 8-fold DIP switch on the I/O module:
4.3.7.1 CAN I/O Module - Inputs and Outputs
X1 CAN interface X2 Analog interface, bootstrap loader interface
X3, X4, X5 Digital inputs 24V X6 Power supply 5V
X7, X8 Digital outputs 24V X9 Power supply 24V
RS232 Analog interface, bootstrap loader
interface
S Main
distributor
sector 2
Subdistrib
utor
sector 4
Comments
1ONONGateway (activate)
2OFF OFF ON: Slio emulation, OFF: CAN I/O module
3OFF OFF Speed (D1/D2: ON: 1Mbit/s), (D4: OFF: 500Kbit/s)
4ONOFFON: Location sector 2, OFF: Location sector 4 (D1/D2: OFF)
5OFF OFF Not in use
6OFF OFF ON: 1-Wire MA, OFF: 1-Wire PC
7OFF OFF Not in use
8OFF OFF Terminating resistor OFF (not used) (D1/D2: ON)
NOTE:
For the assignment of inputs and outputs on D-series machines, refer to the applicable circuit
diagrams or respective texts in the SITEST I/O menu.