JO-109-002_JG-0209.pdf - 第109页

4-21 JO-109 1005-001 2. Feeder Measurement (15) Move the micrometer until the hole of the master tape is aligned with the center of the crosshair . As for the 8 mm feeder , it must be aligned with the pickup position on …

100%1 / 175
4-20
JO-109
1005-001
2. Feeder Measurement
Table D4
Models X Y
G*-0808*, GT-2404*, SL-4808*
-
3.650
-
13.000
G*-1216* or more
-
13.950
-
13.000
Align the hole at the
fiducial mark position
with the center of the
crosshair.
X/Y Position on
Computer Screen
Fig. D20
(13) Press the [Space] key on the keyboard or the [X/Y Measurement]
button in the window to perform the measurement of the ducial
mark position.
(14) Then, measure the pickup position.
The following dialog box appears for three seconds.
Fig. D21
4-21
JO-109
1005-001
2. Feeder Measurement
(15) Move the micrometer until the hole of the master tape is aligned
with the center of the crosshair.
As for the 8 mm feeder, it must be aligned with the pickup
position on Lane #1.
8 mm Tape Feeder
Lane #1
Lane #2
Fig. D22
Note
The pickup position of each model is based on the X/Y
coordinates of the computer screen and almost located at the
coordinates in the following table.
Move the cursor to the position where the hole of the master
tape can be visible perfectly and perform the measurement.
As for the Y direction, the position varies by 0.5 mm (8 mm
feeder) and 1 mm (12 mm or wider feeder).
Ref
.: The variation occurs because the lane origin offset is set
to "0" (zero) at the measurement.
Table D5
Models X Y
G*-*808*
SL-4808*
Lane #1 0.000 0.000
Lane #2 9.500 0.000
G*-1216* 4.100 -2.000
G*-2432* -2.600 -6.000
G*-4456* -8.600 -14.000
G*-7200* -8.600 -14.000
G*-8800* -8.600 -14.000
GT-2404*
Lane #1 1.700 0.000
Lane #2 11.200 0.000
4-22
JO-109
1005-001
2. Feeder Measurement
(16) Press the [Space] key on the keyboard or the [X/Y Measurement]
button in the window to perform the measurement of the pickup
position.
When this operation is performed, the master tape is
automatically fed to the next pickup position after the
measurement is completed.
(17) After that, align the hole of the master tape with the center of the
crosshair again.
(18) Follow the same procedure as in (16) and perform the
measurement.
(19) The measurement is repeated the specied number of times.
Note
The defaults (measurement counts) are specied as follows.
Table D6
Models Measurement Counts
G*-*808*, GT-2404*, SL-4808* 10 times
G*-1216* or more 9 times
In the case of "8 mm Feeder", the following message box appears
after the measurement (repeated the above-described number of
times).
Subsequently, follow the same procedure to perform the
measurement for the lane #2 side.
Fig. D24