4-33 JO-109 1005-001 2.2 Operation Procedure for [Measurement T ype 5] 2.2 Operation Procedure for [Measurement T ype 5] • Lane Original Offset Adjustment and Recognition Mark Position Adjustment This operation is used t…

100%1 / 175
4-32
JO-109
1005-001
2.1 Operation Procedure for [Measurement Type 4]
(13) The following dialogue box window is displayed.
When the offset data calculated based on the teaching data is to
be changed, press the [Yes] button. When it is not to be changed,
press the [No] button.
When the measurement results are written in the feeder, click [Yes].
Fig. D38
(14) When the transfer of the measurement results for writing them in
the feeder, is completed, and the following message "Take out the
feeder" is displayed, remove the feeder.
When the data transmission is completed and this message is
displayed, take out the feeder.
Fig. D39
Notice
During the data transfer to and writing in the feeder, do
not remove the feeder.
4-33
JO-109
1005-001
2.2 Operation Procedure for [Measurement Type 5]
2.2 Operation Procedure for [Measurement Type 5]
Lane Original Offset Adjustment and Recognition Mark Position
Adjustment
This operation is used to perform the complicated processing of the lane
origin offset adjustment and recognition mark position adjustment in a single
inspection, using the sprocket offset value set in the feeder.
When the jig origin teaching only is performed without disassembling or
replacement of driving gear section, adjust it using this [Measurement Type 5]
procedure.
Note
(a) In the automatic type change, this [Measurement Type 5] is selected
preferentially.
(b) This is the inspection type No. only for GT/GD-28081 or 28083.
As an example, the operation procedure in the case that the adjustment for
GD-28081 is performed using the [Measurement Type 5], is described.
Procedure
(1) Select the [Measurement Type 5] program for the corresponding
feeder model type, in the program type setup list.
(1) Select the type name “G D28081-8 × 2_ORG/XY”.
( The yellow-highlighted section shows the currently selected program.)
(2) Click the measurement button.
Fig. D40
4-34
JO-109
1005-001
2.2 Operation Procedure for [Measurement Type 5]
(2) Conrm the program type name displayed in the upper left in the
"Measurement" window.
Confirm the program
type name.
Fig. D41
(3) Connect the feeder to the jig.
When the feeder is to be setup, remove the master tape and light shading jig.
Fig. D42
Note
In the adjustment operation for "Measurement Type 4" or
"Measurement Type 5", rst remove the tape and light shading
jig and then set the feeder.