2.2.4 Overview of Measurements - Progress
Figure 4: Overview of measurements and progress
The following information is shown in the "Progress" menu:
1. All selected measurements are shown at "Measurement Step".
2. The "Status" shows the progress of any measurement currently being performed. If the
measurement has been completed you will see a "green tick for OK" or a "red cross for NOK"!
3. The "Auto details" button is enabled as a default
"Auto details" enabled
The GUI always shows the current measurement as soon as new measurement values
have been found.
"Auto details" disabled
During an ongoing measurement, you can use the arrow keys (black/red) to navigate
through completed measurements, while the current measurement is performed in the
background.
4. The "Previous" button switches over to the previous menu "Selection of Measurements" so
that you can make a new selection.
5. Click the "Start" button (5) to start the measurement and the software will change to the
"Measurement Step“ "Component sensor voltage and Z heights" (in our example)
SIPLACE Head Verification
User Manual Edition 01/2015
12
2.2.5 During Measurements - Progress
After clicking the "Start" button, the machine automatically switches over to measurement mode and
works through the "Selection of Measurements" (chapter 4.2.3) specified.
The following example shows the GUI during the measurement.
Figure 5: During the measurement
The screen (1) shows the segment being measured and the results of the partial measurements. You
can also see whether the measurement for this segment was successful (OK green tick / NOK
red X).
The diagrams (2) show the results of the individual partial measurements.
Select the extraction button to zoom in on the diagram. The diagram bar shows the measurement
values depicted.
If an image is captured with the camera (PCB or component) during measurement, a live image will be
displayed (3).This is not the case in each measurement!
If you want to interrupt or terminate the measurement, use the "Stop" button (4).
The measurement will not stop immediately as the sequence currently running for a segment will be
finished first.
After the procedure has been stopped, click "Continue" to start the process again. The partial
measurement will start again at the beginning and will not just continue from the place at which it was
stopped.
In the event of an emergency stop, click on the "Stop" button and/or the emergency STOP button. The
"Stop" button alone is too slow!
SIPLACE Head Verification
User Manual Edition 01/2015
13
2.2.6 End of Measurement Summary
Figure 6: End of measurement Summary
Once all measurements have been completed, the system will automatically switch over to the
"Summary" menu and the results log (1) appears displaying all data relevant for the head.
You can also view an "Overall Status".
An "Error" is shown if a measurement or just a part of it couldnt be finished successfully.
The whole measurement log can be saved as a PDF by the "Save as File" (2) button after selecting
the storage location.
Click the "Done" button to delete the results. If the results have not been saved as a PDF, they will be
lost and you will need to repeat the measurement.
The "Previous" (3) button takes you back to the previous menu: "Progress".
This menu shows a detailed view of the individual measuring results, as described at 4.2.5.
Figure 7: Scroll through results
Once you are back in the "Progress" menu, you can use the arrow keys (1) to navigate between the
individual measurements.
Use the red arrow (2) to navigate directly to the measurements which have an error.
If the whole measurement was completed with no errors, these red arrows will remain disabled.