X4电路图 - 第210页

2 - 155 LPDT-020101LD3 PCB du al convey or , track 2 conversi on board „Lifting table", place ment se ctors 1 + 2 (sh. 8 of 8) Modified Status Date CAD file : LPDT-020 101LD3_SH08.DWG Orig./Repl.f./Repl.by Stand. Na…

100%1 / 340
2 - 154
LPDT-020101LD3 PCB dual conveyor, track 2
conversion board „Transportation cheek D“ (sh. 7 of 8)
Document st.
Product st.
Function st.
1. Hi
Hi1.
Hi2.
LPDT-020101LD3
10.07.06
10.07.06
10.07.06
20.03.2003
Copyright reserved
SIEMENS AG
WH
BN
BN
WH
W1
W1
Placement sector 1
Cable, belt motor
Intermediate conveyor
Cable, belt motor
Placement sector 2
Cable, belt motor
Cable, belt motor
Cable, belt motor
5
"Conveyor", track 2
28
34
33
30
32
31
29
00359425
(sheet 3)
27
26
25
24
21
22
23
20
19
MOT5-
WH
6
5
4
2
EA5
+24V-
EA7
EA9
EA8
EA6
EA4
EA3
EA2
EA1
GND
EA0
MOT5-
Key
4
MOT5+
MOT4-
W2
00365763
Output conveyor
Key
1
3
2
BN
X5kz
X5.1
1
6
5
WH
MOT4+
MOT3-
00365762
BN
2
3
X4kz
1
6
WH
Key
Conversion board, "transportation cheek"
00365726
To plug X55ku
Conversion board
14
18
17
15
16
13
12
11
10
ModifiedStatus Date
CAD file : LPDT-020101LD3_SH07.DWG
Orig./Repl.f./Repl.byStand.Name
Check.
Mat. no. :
Author Hi
Date
Sh.
Sh.
SIPLACE X-Series
7
8
7
8
9
6
5
4
3
1
2
X16kz
MOT5+
MOT4-
MOT4+
MOT3-
MOT2-
MOT3+
MOT2+
MOT1-
MOT1+
MOT3+
MOT2-
00365761
X3kz
4
3
2
1
BN
6
WH
MOT2+
1
5
4
2
3
BN
Key
00365720
X2kz
Track 2
Side panel D
(kz) 00359424
MOT1-
MOT1+
4
5
6
WH
Key
3
2
BN
2
1
W2
00365719
Input conveyor
X1kz
1
X1.1
55
M
4
6
5
GND
Key
GND
W2
Transmitter, placement sector 2
00370179
Light barrier
Not used
4
M
2
1
3+24V-
EA4
X10kz
5
6GND
BU
1
3
2EA3
+24V-
Key
BN
X9kz
6GND
BU
2
BU
+24V-
EA9
GND
W1
X9.1
1
BN
EA8
+24V-
GND
WH
6
5
4
Key
4
Transmitter, placement sector 2
Light barrier
00365773
1
3
2
BN
X15kz
6
5
Key
WH
Transmitter, placement sector 1
00365771
BN
2
3
X14kz
1
Light barrier
6
Transmitter, placement sector 1
00370177
Light barrier
Transmitter, intermediate conveyor
00370178
Light barrier
M
X8kz
1
3
4
2
+24V-
EA2
Key
BN
6GND
BU
M
1
4
3
5
2EA1
+24V-
Key
BN
X7kz
+24V-
EA7
GND
+24V-
EA6
n.c.
W2
Transmitter, input conveyor
00370176
Light barrier
M
4
3
5
6
2
GND
+24V-
EA0
BU
BN
1
X6kz
Key
3
2
n.c.
BU
X6.1
1
BN
W1
GND
+24V-
EA5
n.c.
BU
Limit switch, width adjustment
X13kz
00365765
4
3
WH
2
1
Key
BN
n.c.
6
BU
3
2
1
4
2
BN
W1
Transmitter, output conveyor
1
W2
5
4
Key
2
3
BN
X12.1
1
Light barrier
00370180
X12kz
4
5
6
Key
3
2
Not used
X11kz
1
Conversion board, "transportation cheek D"
PCB dual conveyor, track 2
See page 5-17
2 - 155
LPDT-020101LD3 PCB dual conveyor, track 2
conversion board „Lifting table", placement sectors 1 + 2 (sh. 8 of 8)
ModifiedStatus Date
CAD file : LPDT-020101LD3_SH08.DWG
Orig./Repl.f./Repl.byStand.Name
Check.
Mat. no. :
Author Hi
Date
Sh.
Sh.
SIPLACE X-Series
8
8
X2ly
3
1
Key
GN
BN
Light barrier, track B
Conversion board
00363080
(ly) 00362766
GND
+24V-
4
6
5
2
3
1
X1ly
1
3
4WH
BN
GN
Light barrier, track A
Conversion board
00363079
Key
5
GND 6
5
4
BK
Key
Valve, lifting table down
4
+24V-
1
3
2
X5lz
GND 6
5
Conversion board
BK
00363077
BK
+24V-
2
3
1
X4lz
GND 6
Conversion board
BK
00363078
Key
Valve, lifting table up
BU
Key
Conversion board, "lifting table"
Lifting table 2, valve down
Lifting table 2, valve up
Lifting table 2, limit switch
Lifting table 2, track B
Lifting table 2, track A
+24V-
GND
10
To plug X2ku
Conversion board
"Conveyor", track 2
(sheet 4)
00359425
00369074
7
8
9
6
5
X6lz
4
3
1
2
Placement sector 2, track 2
(lz) 00362766
X3lz
+24V-
4
3
2
1
GND 6
00363076
BN
BK
Limit switch
Lifting table with cable
WH 4
1
+24V-
5
4
2
3
X2lz
Key
GN
BN
3
1
Light barrier, track B
Conversion board
00363080
+24V-
GND
4
5
6
3
2
X1lz
1
WH
BN
GN
4
1
3
Light barrier, track A
Conversion board
00363079
Key
Conversion board, "lifting table"
Placement sectors 1 + 2
PCB dual conveyor, track 2
Document st.
Product st.
Function st.
1. Hi
Hi1.
Hi2.
LPDT-020101LD3
10.07.06
10.07.06
10.07.06
20.03.2003
Copyright reserved
SIEMENS AG
5
GND 6
5
4
BK
Key
4
+24V-
1
2
3
X5ly
GND
5
6
Valve, lifting table down
Conversion board
BK
00363077
BK
+24V-
2
3
1
X4ly
GND 6
Conversion board
BK
00363078
Key
Valve, lifting table up
BU
Key
Lifting table 1, track A
Lifting table 1, track B
Lifting table 1, limit switch
Lifting table 1, valve up
Lifting table 1, valve down
GND
Placement sector 1, track 2
+24V-
Conversion board, "lifting table"
10
Conversion board
"Conveyor", track 2
To plug X1ku
00359425
(sheet 4)
00369073
7
8
9
6
5
X6ly
4
3
1
2
X3ly
+24V-
3
4
1
2
GND 6
00363076
BN
BK
Limit switch
Lifting table with cable
4WH
1
+24V-
5
4
2
3
See page 5-20 See page 5-20
SIPLACE X-Series Detailed Circuit Diagrams Folder
08/2006 US Edition
3 - i
3 Circuit diagrams
00354626-130101LD4 Power supply (sh. 1 of 7) 3 - 1
00354626-130101LD4 Power supply (sh. 2 of 7) 3 - 2
00354626-130101LD4 Power supply (sh. 3 of 7) 3 - 3
00354626-130101LD4 Power supply (sh. 4 of 7) 3 - 4
00354626-130101LD4 Power supply (sh. 5 of 7) 3 - 5
00354626-130101LD4 Power supply (sh. 6 of 7) 3 - 6
00354626-130101LD4 Power supply (sh. 7 of 7) 3 - 7
03005159-010801FD3 Overview, electrical connections, C&P20 3 - 8
03039079-010201LD3 A364 axis unit, wiring (sh. 1 of 2) 3 - 9
03039079-010201LD3 A364 axis unit, wiring (sh. 2 of 2) 3 - 10
03046225-010101LD3 Main distributor (sh. 1 of 4) 3 - 11
03046225-010101LD3 Main distributor (sh. 2 of 4) 3 - 12
03046225-010101LD3 Main distributor (sh. 3 of 4) 3 - 13
03046225-010101LD3 Main distributor (sh. 4 of 4) 3 - 14
03046226-010101LD3 Sub-distributor (sh. 1 of 4) 3 - 15
03046226-010101LD3 Sub-distributor (sh. 2 of 4) 3 - 16
03046226-010101LD3 Sub-distributor (sh. 3 of 4) 3 - 17
03046226-010101LD3 Sub-distributor (sh. 4 of 4) 3 - 18
03048274-010101LD4 Computer unit 3 - 19
TEMP13_X2-010101LD3 Temperature compensation, SIPLACE X2, gantries 1 and 3 3 - 20
TEMP14_X3X4-010101LD3 Temperature compensation, SIPLACE X3 and X4, gantries 1 and 4 3 - 21
TEMP23_X3X4-010101LD3 Temperature compensation, SIPLACE X3, gantry 3
SIPLACE X4, gantries 2 and 3 3 - 22
PE-010101LD3 Grounding cable, overview 3 - 23