X4电路图 - 第59页

2 - 4 NH-070 101LD3 Emerge ncy stop loop, EM ERGENC Y STOP but tons, ST ART/STOP buttons, pr otecti ve switche s (sh. 4 of 7) n.u. 7 BU RD 03002524 S_StartButton +24V EARTH ING Terminal used Terminal not used X1qa_StartB…

100%1 / 340
2 - 3
NH-070101LD3 Emergency stop loop, protective switches
CO trolley docking unit, SIPLACE HF (sh. 3 of 7)
Document st.
Product st.
Function st.
1. Hi
Hi1.
Hi7.
NH-070101LD3
10.07.06
10.07.06
10.07.06
11.01.2005
Copyright reserved
SIEMENS AG
Protective switch, component trolley, docking unit
SIPLACE HF
X72qa_2_S_EmergencyStopButtonMTC
EmergencyStopLoopMTC2Out
EmergencyStopLoopMTC2In
2Vin(-)Illumination 9
Power supply
GND_P
00354626
(sheet 1)
X16:7
X16:8
X16:10
X16:11
F12
GND_P
F12
GND (+24V)
GND (+5V)
+24V
Vin(+)Illumination
8
7
4
1
6
5
3
2
+5V
Vin(-)Illumination
Vin(+)Illumination
n.u.
2
3
4
2
1
X18
1 1
(sheet 4)
X1qa_Vin(+) illumination
(W5)
sub-distributor
(W6)
(W5)
(W6)
(W6)
(sheet 5)
X3ra
03002506
(W4)
(W6)
(W4) 9
8
GY
n.u.
03046225 (qa)
Main distributor
WH (W4)
BN (W4)
GN (W4)
WH (W3)
BN (W3)
GN (W3)
YE (W4)
GY (W4)
CSC43 13
CSC53
CSC44
CSC54
6 2
4
5
2
1
n.u.
n.u.
2
1
X17
EmergencyStopLoop1OK
X20:3
X20:4
X20:6
X20:5
+24V
GND (+24V)
12
10
11
+5V
n.u.
VoltageTapeCutter
GND (+5V)
9
ModifiedStatus Date
CAD file : NH-070101LD3_SH03.DWG
Orig./Repl.f./Repl.byStand.Name
Check.
Mat. no. :
Author Hi
Date
Sh.
Sh.
SIPLACE X-Series
3
7
Emergency-stop loop
2+3
(W1)2
6
10 9
7
8
5
4
3
(W1)6
(W1)8
(W2)
(W1)9
YE
(W1)7
(W1)
(W1)5
4
(W2)
(W2)BN
WH
X133
1
2
n.u.
n.u.
11
12
11 10
(W1)1
11 (W1)
(W2)
(W1)3
GN
(W1)
(W1)10
9
E29/30
C29/30
B28/30
D29/30
A29/30
Component trolley
SIPLACE HF, location 3
BK
RD
1
4
2
3
n.u.
BK
n.u.
CO flap
Adapter connector
03021042
X13f
Component trolley, docking unit
SIPLACE HF, location 3
X130
Component trolley
E29/30
D29/30
B29/30
C29/30
A29/30
X120
SIPLACE HF, location 2
RD
BK
03021020-W1/W2
X14qa X53
EmergencyStopLoopMTC2Out
EmergencyStopLoopMTC2In
S_COTable2
S_Flap
EmergencyStopLoop1Out
EmergencyStopLoop1In
+24V
03002531
GND
+24V
GND
S_Hood3
EmergencyStopLoop1In
EmergencyStopLoop1Out
X1qa_0V
3
2
5
6
7
8
4
BK
X5qb_3 (DI18)
(sheet 4)
X1qa_M_Flap
BK
BK
BK
(sheet 4)
X1qa_24V
BK
BK
+24V
OG
6
9
8
7
4
5
2+3
1
1
2
4
6
5
3
(sheet 4)
X1qa_0V
GND
WH
GND
n.u.
WH
X24qa_4
(sheet 4)
X1qa_24V
BK
BK
+24V
OG
BK
GNYE+1
X18qa
RD
WH+BN
GY+PK
GN+YE
BU
5
8
7
6
3
4
2
(W1)5
(W2)
(W1)
YE
8
(W1)
(W1)6
7
(W2)
(W1)4
BN
(W1)
(W2)WH
2
WH+BN
GN+YE
GY+PK
BU
n.u.
X123
1
6
5
4
3
1
2
(W1)1
22
21
03002528-W1
S_Hood2
EmergencyStopLoop1Out
EmergencyStopLoop1In
+24V
GND
03002527-W1
1
2
3
5
4
6
BK
X19qa_4
(sheet 4)
X1qa_0V
n.u.
GND
WH
BK
(sheet 4)
X1qa_24V
X72qa_4
OG
+24V
BK
(sheet 4)
X12qa_3
GY+PK
RD
BU
WH+BN
GN+YE
X13qa
WH+BN
BU
GY+PK
GN+YE
n.u.
6
5
4
1
2
3
X52
03020409
22
03020409
21
X12f
4
3
2
1
n.u.
n.u.
BK
03021042
CO flap
Adapter connector
SIPLACE HF, location 2
Component trolley, docking unit
Hood switch
Location 3
12
11
12
Location 2
Hood switch
11
(sheet 4)
(sheet 4)
(sheet 4)
(sheet 6)
n.u.
n.u.
n.u.
n.u.
n.u.
n.u.
n.u.
n.u. n.u.
n.u.
n.u.
n.u.
8
7
6
EmergencyStopLoop1End
S_Ready
StartButtonOn
S_GantryCrash
Software_CtrlOn
3
4
5
2
1
X16
X1qa_Software_CtrlOn
CSC54
CSC53
CSC44
CSC43
EmergencyStopLoop1OK
GND (+24V)
GND (+5V)
VoltageTapeCutter
X1qa_0V
(W2)
(W3)
(W2)
(W3)
03002506
BK3
7
6
4
5
WH
BK
BK
BK
2
1
X3qa
n.u.
n.u.
1 (W2)
2 (W2)
2 (W1)
1 (W1)
12
10
11
BK
+24VOG
WH
9
8
7
6
n.u.
WH
+5VPK
BK
CAN I/O module
X1qa_0V
X3qb_1 (DI0)
X1qa_24V
X1qa_0V
X1qa_5V
Software_CtrlOn
EmergencyStopLoop1End
StartButtonOn
03002505
3
4
5
2
1
n.u.
BK
BK
S_Ready
BK
BK
X2qa
X1qa_StartButton
CAN I/O module
X4qb_2 (DI9)
(sheet 4)
X71qa_6
X72qa_3
X73qa_9
10BK 10+1199
03021020-W1/W2
n.u.
n.u.
12
11
11 10
(W1)3
(W2)GN
(W1)
(W1)11
10
S_COTable3
S_EmergencyStopButtonMTC
S_Flap
EmergencyStopLoop1In
EmergencyStopLoop1Out
+24V
GND
03002535
OG
X1qa_24V
3
5
6
7
8
4
9
X5qb_7 (DI22)
(sheet 4)
X1qa_M_Flap
n.u.
BK
BK
n.u.
(sheet 4)
n.u.
BK
BK
7
10+11
8
9
6
5
4
1
2
X1qa_0V
GND
+24V
WH GNYE+1
X23qa
See page 4-9
2 - 4
NH-070101LD3 Emergency stop loop, EMERGENCY STOP buttons,
START/STOP buttons, protective switches (sh. 4 of 7)
n.u.
7
BU
RD
03002524
S_StartButton
+24V
EARTHING
Terminal used
Terminal not used
X1qa_StartButton
X1qa_StopButton
X7qb_5(DO4)
X1qa_24V
BK
2
BN
n.u.
4
BK
WH
GND
6
5
BK
3
YE
GY
PK
GN
X9qa
OG
+24V 1
WH
S_StartButton
Ctrl_COCounter
S_StopButton
GND
03002523
+24V
CO counter
6
Pneumatic panel
YE
3
WH (W1)
X62
4
3
BN
RD
2
1
OG
BN
(W2)
(W2)
(W2)
(W1)
4
n.u.
03020410
S1
3
4
4
Stop
S2
Start
3
4
03004702
2
GN
WH
1
X57
BN
n.u.
n.u.
n.u.
8
9
7
BU
3
4
3
Stop
S2
Start
S1
5
1
Power supply panel
GN
2
n.u.
4
6
5
PK
GY
3
YE
WH
1
BN
X56
03004701
S2
4
Stop
4
3
3
Start
S1
(sheet 3) (sheet 3)
(sheet 3)
(sheet 2)
(sheet 3)
(sheet 3)
(sheet 2)
22
21
19
17
16
15
14
X18qa_7
DI23
DI22
BK
DI20
DI21
DI19
BK
BK
BK
X24qa_4
X23qa_7
X12qa_4
X11qa_4
DI17
DI18
DI16
BK
BK
OG
X19qa_4
X1qa_24V
12
11
10
Bridge
7
9
8
6
X7qb
A1 (qb)
Ctrl_CompressedAirPressure C&P/TWIN
2
Software_CtrlOn
Ctrl_ComponentCounter
5
n.u.
n.u.
6
7
n.u.
3
4
n.u.
1
X1qa
DO1
BK
BK
DO4
DO6
DO5
DO3
DO2
BK
X9qa_5
K2_A2
DO0
4
3
2
1
X1qa
Terminals overview
ab c d
PCB output, right-h. side
GN (W1)S_StartButtonBU
5
BK
5
X5qb_5 (DI20)
X1qa_StopButton
X1qa_StartButton
X13qa_2
(sheet 2)
BK
BK
6
5
RD
BU
S_StopButton
S_StartButton
X1qa_24V
Vin(+)Illumination (DC/DC converter)
StopButton
Flap
StartButton
Software_CtrlOn
X1qa_StopButton
X1qa_StartButton
S_Emerg.StopButtonPCBoutput
WH
+24V
OG
1
BK
2
BK
BK
4
3
BN+GN
YE+GY
PK
X12qa
+24V
EmergencyStopLoop1In
EmergencyStopLoop1Out
03002526
BK
6
RD S_StopButton
B1 WH
Emergency-stop
2111
6
5
VT
BK
12 22
S3
Cover flap, PCB conveyor
PCB output side, on the left
1
BN
YE+GY
PK+BU
2
4
3
RD
GN
X63
WH
Stop
4
4
3
3
S2
Start
S1
03020687
n.u.
7
9
8
n.u.
BK
6
YE
(W2)
(W1)
PCB output, right-h. side
22 12
21 11
X1qa_0V
+24V
-15V
+15V
X5qb_4 (DI19)
X1qa_24V
X1qa_StopButton
+5V
GND
X1qa_StartButton
X1qa_24V
BK S_StopButtonYE
3
X11qa
BK
BK
4
3
OG
BK
+24V
2
1
PK
YE+GY
WH
BN+GN
n.u.
4
S_HoodPCBoutput
EmergencyStopLoop1Out
EmergencyStopLoop1In
+24V
WH
03002525
X10qa
BK
2
OG
+24V 1
GN
WH+BN
8
n.u.
n.u.
9
Document st.
Product st.
Function st.
1. Hi
Hi1.
Hi7.
NH-070101LD3
10.07.06
10.07.06
10.07.06
11.01.2005
Copyright reserved
SIEMENS AG
Emergency-stop push-button, START buttons, STOP buttons
Protective switch
Main distributor
03046225 (qa)
WH
GND
X1qa_0V
WH
X1ra_0V
GN+YE (W3)
99
03002521
(W2)
(W2)
(W2)
(W1)
(W1)
(W1)
03002520
X24ra_7
X3rb_1
9
BK
n.u.
8
n.u.
7
RD
BU
X4ra_6
X1ra_StartButton
X1ra_StopButton
X1ra_Flap
GN
3
BK
5
BK
BK
6
4
n.u.
n.u.
GY
PK
YE
X73ra
BK
2
BK
1
BN
WH
X23ra_9
X23ra_5
X23ra_6
X23ra_4
BK BN
2
n.u.
BK
6
5
BK
3
BK
4
GN
BN
WH
GN
X72ra
1
n.u.
WH
X24qa_7
X2qa_6
EmergencyStopLoop1OK
X2qa_12
(sheet 2)
9
8
7
BK
n.u.
n.u.
(sheet 2)
X3qa_6
X3qa_5
X18qa_9 S_EmergencyStopButtonMTC
X4qa_6
X1qa_Flap
X1qa_StartButton
X1qa_StopButton
3
5
6
4
BK
BK
BK
n.u.
n.u.
2
1
X73qa
BK
BK
ModifiedStatus Date
CAD file : NH-070101LD3_SH04.DWG
Orig./Repl.f./Repl.byStand.Name
Check.
Mat. no. :
Author Hi
Date
Sh.
Sh.
SIPLACE X-Series
4
7
Emergency-stop loop
EmergencyStopLoopMTC4In
EmergencyStopLoopMTC4Out
EmergencyStopLoop1Input
BK
2
6
5
3
4
BK
n.u.
BK
BK
1
X72qa
n.u.
27
29
28
25
26
24
23
W1+W2
X4bm / X4cm
SST33
CAN I/O module
EmergencyStopLoop1OK
(W3)
(W3)
(W3)
03002519
DI7
1
X2rc_8(VIlluminationB)
X2rc_4(VIlluminationA)
X17ra_4
n.u.n.u.
GY
7
GY
8
BK
6
2
3
1
n.u.
3
n.u.
5
4
n.u.
2
n.u.
n.u.
n.u.
n.u.
n.u.
Sub-distributor
03046226 (ra)
(sheet 4)
X71ra
n.u.
8
X2qa_12
X1qa_Flap
DI1
2
n.u.
DI4
DI6
DI5
BK
DI3
DI2
5
n.u.
n.u.
n.u.
6
7
S_Flap
n.u.
3
4
BK
DI0
1
X3qb
5
DO7
X5qb
GNDWH
1
X1qa_0V
X1qa_24V
X2qc_8 (VLT33)
X1qa_0V
X2qc_7_VoltageIlluminationB
X2qc_9_VoltageIlluminationA
X17qa_4
Voltage tape cutter
n.u.
7
8
6
GY
GY
BK
BK
3
5
4
2
GY
WH
GND
OG
S_Emerg.StopButtonPCBoutput
X71qa
S_COTable2
3
S_HoodPCBoutput
S_COTable3
S_Hood3
6
n.u.
8
7
5
4
S_EmergencyStopLoop2OK
S_Hood2
2
1
n.u.
8
13
18
20
See page 4-9
See page 5-14
2 - 5
NH-070101LD3 Emergency stop loop, protective switches
CO trolley docking unit, SIPLACE X-series (sh. 5 of 7)
ModifiedStatus Date
CAD file : NH-070101LD3_SH05.DWG
Orig./Repl.f./Repl.byStand.Name
Check.
Mat. no. :
Author Hi
Date
Sh.
Sh.
SIPLACE X-Series
5
7
Emergency-stop loop
3
11
10 9
10
8
5
7
6
4
2
X113
1
n.u.
6
5
03002540
+24V
S_Hood4
EmergencyStopLoop1In
EmergencyStopLoop1Out
X14ra
BK
BK 4
BK
3
OG
1
2
X13ra_3
GN+YE
BU
GY+PK
WH+BN WH+BN
GN+YE
GY+PK
BU
X54
4
3
1
2
22
21
03020409
Hood switch
Location 4
22
n.u.
Component trolley
SIPLACE X-Series, Location 1
(W1)GN
GN (W2)
n.u.
n.u.
n.u.
n.u.
n.u.
YE
BN
YE
(W2)
(W1)
(W1)
n.u.
WH
WH
BN
GN
GN
03019057-W1/W2
(W2)
(W2)
(W1)
(W1)
(W2)
31
Component trolley
SIPLACE X-Series, Location 4
32
docking unit
Location 4
SIPLACE X-Series
Component trolley
4
3
22
21
12
11
S1
CO flap
Adapter connector
03021042
X14f
2
1
32
31
BN (W2)
n.u.
n.u.
n.u.
n.u.
YE
BN
YE
(W2)
(W1)
(W1)
WH
WH
n.u.
03019057-W1/W2
(W2)
(W1)
Location 1
docking unit
SIPLACE X-Series
2
Component trolley
4
3
21
12
11
S1
Adapter connector
03021042
X11f
1
CO flap
n.u.
BK
n.u.
n.u.
BK
n.u.
(sheet 7)
Document st.
Product st.
Function st.
1. Hi
Hi1.
Hi7.
NH-070101LD3
10.07.06
10.07.06
10.07.06
11.01.2005
Copyright reserved
SIEMENS AG
Protective switch, component trolley, docking unit
SIPLACE X-Series
(sheet 7)
X5rb_7 (DI22)
X5rb_3 (DI18)
X24ra_4
(sheet 7)
(sheet 7)
(sheet 7)
(sheet 7)
X1ra_Flap
X1ra_Flap
X1ra_0V
X1ra_24V
X1ra_24V
X1ra_0V
X1ra_0V
X1ra_24V
X1ra_StopButton
X3ra
8
1 (W5) 9
(sheet 1)
X18
power supply
03002506
3
2
4
3
(W5) 7
6
(W6)
(W6)
5
4
1
2
(W6) 1
(W6) 2
(sheet 4)
03002521
X73qa
main distributor
RD
9
BU
7
8
PK
GY
6
5
YE
GN
4
3
Vin(+)IlluminationGY
n.u.
X1ra_Vin(+)Illumination
(sheet 7)
n.u.
Vin(-)Illumination
GND24V
WH
n.u.
WH
OG +24V
GND5V
+5VPK
WH
X1ra_0V
X1ra_24V
X1ra_0V
X1ra_0V
X1ra_5V
EmergencyStopLoop1OK
n.u.
BK
n.u.
S_ControlOnBK
BK S_Flap
n.u.
n.u.
CAN I/O module
X3rb_1(DI0)
X24ra_7
X4ra_6
X1ra_Flap
(sheet 7)
CAN I/O module
X4rb_8(DI15)
X71ra
X72ra
X73ra
BN (W1)
2
main distributor
X72qa
03002520
(sheet 4)
WH
BN
1
2
WH
GN
BN
GN
(W2)
4
(W2)
(W2)
6
5
(W1)
3
03002519
X71qa
(sheet 4)
main distributor
(W3)GN+YE
WH (W1)
1
2
3
1
(W3)
7
(W3)
8
9
(W3)
6
5
4
3
1
2
03046226 (ra)
BK S_EmergencyStopButtonMTC
EmergencyStopLoop1Input
EmergencyStopLoopMTC4In
EmergencyStopLoopMTC4Out
S_StopButton
S_StartButtonBK
BK
BK
n.u.
BK
BK
X1ra_StartButton
(sheet 7)
WH
n.u.
VoltageTapeCutter
VoltageIlluminationA
VoltageIlluminationB
GY
GY
GND
BK
n.u.
(sheet 7)
X1ra_0V
(VillB)
(VillA)
X2rc_8
X2rc_4
X17ra_4
n.u.
n.u.
n.u.
n.u.
Sub-distributor
n.u.
11
12
n.u.
S_EmergencyStopButtonMTC
EmergencyStopLoopMTC4Out
EmergencyStopLoopMTC4In
S_COtable4
S_Flap
EmergencyStopLoop1In
EmergencyStopLoop1Out
+24V
GND
03002547
BK
BK
9
BK
6
BK 7
8
BK
5
BK
4
10+11
7
9
8
6
5
X23ra
BK
3
WH
1
OG
2
GNYE+1
4
2+3
n.u.
11
10
11
10
9
6
7
8
5
4
X143
3
1
2
n.u.
12
12
11
S_COtable1
S_Flap
EmergencyStopLoop1out
EmergencyStopLoop1in
+24V
03002542
GND
GND
BK
43
9
n.u.
BK
8
n.u.
5
n.u.
BK 7
6
BK
4
10+11
9
6
8
7
5
X18ra
OG
2
WH
1
WH
6
n.u.
5
GNYE+1
2+3
RD
See page 4-10