Process Lens PL Service Manual_EN.pdf - 第126页

3 Replacing spare parts 12 6 Se rv ic e Ma nu al P ro ce ss L en s PL - 0 3/ 20 25 3.5.2.5 Changing the motor of the lifting table Parts 03064983-xx BLDS motor with PLG and brake Equipment and tools ● Allen key size 5.0 …

100%1 / 168
3 Replacing spare parts
Service Manual Process Lens PL - 03/2025 125
Fig.177: “System Test” tab
► Open the Diagnostic page.
► Go to the tab System Test(1).
► Click on the button Track zero point cali-
bration(2).
► A message will indicate that the calibration
was successful.
Fig.178: “Unit function” tab
► Go to the tab Unit function(3).
► Proceed to the conveyor section and press
the buttons Lift Home(4), Lift up(5) and
Lift down(6) to check the function of the
lifting table.
► On screen messages will confirm the suc-
cessful function test of the lifting table.
► If the conveyor system does not move or
any fault message occurs, the conveyor
system needs to be adjusted.
3 Replacing spare parts
126 Service Manual Process Lens PL - 03/2025
3.5.2.5 Changing the motor of the lifting table
Parts
03064983-xx BLDS motor with PLG and brake
Equipment and tools
●
Allen key size 5.0
Requirements
●
Machine is switched off.
Remove the motor of the lifting table
Fig.179: Lifting plate
1. Screw (4 x)
2. Motor of the lifting table plate
3. Lifting table plate
► Unscrew the screws(1) off the lifting table
plate(3) using an Allen key size 5.0.
► Remove the lifting table plate(3).
► Disconnect all connectors from the
TSP400.
Fig.180: Lifting table motor
► Unscrew the 3 screws(1) off the lifting
table motor using an Allen key size 5.0.
3 Replacing spare parts
Service Manual Process Lens PL - 03/2025 127
Fig.181: Lifting table motor
1. Stopper screw
2. Cam
3. Screw A
► Unscrew screw A(3) from the cam(2)
using an Allen key size 5.0.
► Remove the motor.
Replace the motor of the lifting table
Parts
03064983-xx BLDS motor with PLG and brake
Equipment and tools
●
Allen key size 5.0
Requirements
●
Machine is switched off.
●
The motor of the lifting table is dismantled.
●
The lifting table plate is dismantled.
► Position the lifting table motor.
► Connect the connectors at the TSP400.
Fig.182: Lifting table motor
1. Stopper screw
2. Cam
3. Screw A
► Put the cam(2) in the right position so that
the cam hits the stopper screw(1). Fasten
the screw of the cam using an Allen key
size 5.0.
 NOTICE!
Positioning of the cam
The cam must be in the position as shown
in the picture when the screw is tightened.
It must hit the stopper screw.
.