Process Lens PL Service Manual_EN - 第165页

4 Machine - Calibrations Se rv ic e Ma nu al P ro ce ss L en s PL - 0 3/ 20 25 16 5 Fig.261: Messages ► Inspection will stop when Board Count reach Board Limit set (1) . ► A pop-up message (2) will appear, click Ok to…

100%1 / 168
4 Machine - Calibrations
164 Service Manual Process Lens PL - 03/2025
Fig.258: Messages
Click GRR Setting(1).
Pop up menu will appear, click Ok(2).
Fig.259: Messages
Enter No. of Board(1).
Select 0 Degree(2).
Click Generate Recipe(3). This will take
some time.
Fig.260: Messages
Click Inspection(1).
Click Proceed to 0 Degree(2).
Close the window(3), GRR will start.
4 Machine - Calibrations
Service Manual Process Lens PL - 03/2025 165
Fig.261: Messages
Inspection will stop when Board Count
reach Board Limit set(1).
A pop-up message(2) will appear, click
Ok to close.
Fig.262: Messages
Click Display Result(1).
Click Filter Option(4).
Click Select All Pads(2).
Click Ok(3) to all message boxes to gen-
erate the Repeatability Report.
Fig.263: Reports
Examine each of the 5 measurement vari-
ables (1).
Check that all the %GR&R are less than
10%. (2)
e.g. Volume(%) repeatability for all the dif-
ferent orientations are less than 10%
which is good.
Click Report GR&R (3) to produce a
report.
Click Export PDF (4) to export the GR&R
results.
Repeat for all measured variables. Keep
the report as proof of GR&R capability.
4 Machine - Calibrations
166 Service Manual Process Lens PL - 03/2025
What to do if the GR&R fails?
Measure again: fiber, dust could have fallen on the pad during GR&R test.
Is the machine cover opened? Is the board properly clamped?
Is the board bouncing because it´s thin, not properly supported?
Is the paste on the board slumping? Check for hardware issues.
Was there any disturbance to the CR&R process to the target?