3 Replacing spare parts Se rv ic e Ma nu al P ro ce ss L en s PL - 0 3/ 20 25 21 3 Replacing spare parts NOTICE For a list of spare parts refer to the spare parts catalogue. 3.1 Vision module 3.1.1 Optical head 3.1.1.1 R…

100%1 / 168
2 General
20 Service Manual Process Lens PL - 03/2025
3 Replacing spare parts
Service Manual Process Lens PL - 03/2025 21
3 Replacing spare parts
NOTICE
For a list of spare parts refer to the spare parts catalogue.
3.1 Vision module
3.1.1 Optical head
3.1.1.1 Replacing the optical head
Parts
03122959-xx Vision Module
03250225-xx Vision head DMD
●
Single Lane: PL-0144 and above
●
Dual Lane: PD0030 and above
Equipment and tools
●
Allen key size 2.5
Requirements
●
Machine is switched off.
Removal
Fig.3: Moving optical head to the middle of the machine
► Move the optical head(1) carefully to the
middle of the machine.
 CAUTION!
Sensitive camera system
The camera system is very sensitive and
must therefore not be touched.
Make sure you don’t touch the camera
when moving the gantry.
.
3 Replacing spare parts
22 Service Manual Process Lens PL - 03/2025
Fig.4: Removing the cover
► Remove the cover(2) that protects the
connection spots for the cables by un-
screwing the screws(1) by using an Allen
key size 2.5.
► Place the dismantled cover on a service
table.
Fig.5: Unplugging the cables
► Remove the cable clamp(2) that fixes the
cables by unscrewing the screws(1) using
an Allen key size 2.5.
► Place the dismantled cable clamp(2) on a
service table.
► Unplug the cables.
 CAUTION!
Sensitive camera system
The camera system (3) is very sensitive.
Therefore do not touch the camera sys-
tem to avoid damage to it.
.
► Carefully put the cables aside.
Fig.6: Removing the cable connectors
► Remove the two screws(1) mounted on
top of the optical head fixing the ribbon
cable connectors using an Allen key size
2.5.
► Remove the ribbon cable connectors out
of the sockets by pulling the clamps apart.