CP43维护手册.pdf.pdf - 第30页
Chapter 2 Setting Up the CP IV -3 2 – 8 V ersion 4.0

Chapter 2 Setting Up the CP IV-3
2.7 Checking the Three Phase Cable Wiring
By checking the direction of motor rotation, the wiring of the machine can
also be checked. If the motor direction is correct then the wiring is also
correct. This check can be performed without the 200V power supply.
(1) Engage the 100V power supply.
(2) Pull the station 8 spool out.
(3) Place one finger on the tip of the nozzle and check for air suction. If
air suction is detected, the wiring has been set up correctly, and the
motor is rotating in the correct direction. If air is expelled, change the
U and V phase of the three-phase cable wiring and repeat steps (1) to
(3) to check for air suction.
2 – 7
Version 4.0

Chapter 2 Setting Up the CP IV-3
2 – 8
Version 4.0

Chapter 3 Parts of the Machine
3. Parts of the Machine
Listed herein are the names of the parts of the machine as they are referred to in
this manual.
Fig. 3-1 Front View of the Machine
Version 1.0 3 – 1