141-400-57-probestationaccessoriescatalog - 第120页
PN 141-400 www.formfactor.com Probe Mounts/Holders and Pro bes • 1 04 Revision 57, February, 2023 Probe Station A ccessories 100 69 6 — P r ob e Arm, DPP 2x x/D PP 3x x, Ke lvin , 1 Tip Feat ur es • ( 2) 2 m (6.5 ft) coa…

PN 141-400 www.formfactor.com Probe Mounts/Holders and Probes • 103
Revision 57, February, 2023 Probe Station Accessories
Probe Mount s/Holders and Probes
Probe Arms and Probes (S-Positioner Compatible)
DC PROBE ARMS, DPP2XX/DPP3XX
100489 — Ad apter Picoprobe 10-34A/DPP2xx/DPP3xx
Features
• Holding fixture for active picoprobes
from GGB picoprobe 10…34
(picoprobe not included)
• Integrates existing picoprobe with
DPP2XX or DPP3xx
• Ada pter is included with FormFactor
standard picoprobes
Compatibility
• MPS150, PM8, PM300, PA200, PA300
100524 — Probe Arm, DPP2xx/DPP3xx, Edge Sensor
Features
• Includes edge sensor tip
• With connector matching to all semiautomatic
standard probe stations (check compatibility to
all other probe stations)
Compatibility
• All PA/PM stations (except MicroAlign) +
DPP2xx-S, DPP3xx-S, DPP450-S (and former PH110, PH120,
PH150, PH400)
100525 — Probe Arm, DPP2xx/DPP3xx, Triax
Features
• 1.5 m (5 ft) 5 0 Ohm low n oise triax cable and
triax plug BNC
• Highly isolated and gold plated needle
clamping
Specifications
• Max. operation temperature: 300°C (572°F)
• Res istanc e*:
• Leakage*:
• Capacitance*:
* Spec test conditions for all cases: 25% humidity, shielded chamber, ambient
Compatibility
• MPS150, EPS150, all PA/PM stations (except MicroAlign) +
DPP2xx-S, DPP3xx-S, DPP450-S (and former PH110, PH120,
PH150, PH400)
100560 — Probe Arm, DPP3xx, Coax, BNC
Features
• Short 50 Ohm coaxial cable and female BNC
connector mounted in DPP3xx positioner base
• Requires additional coaxial cable (BNC male
connector)
• Isolated a nd gold plated needle clamping
Compatibility
• MPS150, EPS150, all PA/PM stations (except MicroAlign) +
DPP3xx-S, DPP450-S (and former PH150, PH400)
100561 — Probe Arm, DPP2xx/DPP3xx, Coax, BNC
Features
• 2 m (6.5 ft) 50 Ohm coaxial cable with BNC
connector
• Gold plated needle clamp
Specifications
• Resistance: >100 TOhm
• Leakage: < 120 fA
• Capacitance: <300 pF
Compatibility
• MPS150, EPS150, all PA/PM stations (except MicroAlign) +
DPP2xx-S, DPP3xx-S, DPP450-S (and former PH110, PH120,
PH150, PH400)
R_F-G @10V
T Ω
≥100
R_G-S @10V
T Ω
≥50
R_F-S @10V
T Ω
≥300
F-G @10V@1min
fA
≤500
G-S @10V@1min
fA
≤2000
F-S @10V@1min
fA
≤500
C_F-G @300pA
pF
≤300
C_G-S @300pA
pF
≤500
C_F-S @300pA
pF
≤200

PN 141-400 www.formfactor.com Probe Mounts/Holders and Probes • 104
Revision 57, February, 2023 Probe Station Accessories
100696 — Probe Arm, DPP2xx/DPP3xx, Kelvin, 1 Tip
Features
• (2) 2 m (6.5 ft) coaxial cables, 50 Ohm and
BNC connector
• Double arm design for improved stiffness,
with s ingle tip clamping (gold plated)
• Shield connection can be changed
• Connected for LCR measurements as
standard
Compatibility
• MPS150, EPS150, all PA/PM stations (except MicroAlign) +
DPP2xx-S, DPP3xx-S, DPP450-S (and former PH110, PH120,
PH150, PH400)
100715 — Probe Arm, DPP2xx/DPP3xx, Adjustable,
Coax, BNC
Features
• 2 m (6.5 ft) 50 Ohm coaxial cable and BNC
plug
• Four hinges for individual arm profiling
• Gold p lated needle clamping
Specifications
• Res istanc e: >100TOhm
• Leakage: <120fA
• Capacitance: <300pF
Compatibility
• MPS150, EPS150, all PA/PM stations (except MicroAlign) +
DPP2xx-S, DPP3xx-S, DPP450-S (and former PH110, PH120,
PH150, PH400)
131844 — Probe Arm, DPP2xx/DPP3xx, Coax, High
Temperature
Features
• For long term tests at temperatures higher
than 100°C and always with temperature
chucks up to 300°C
Specifications
• 1.5 m (6 ft) 5 0 Ohm c able with coaxial plug
BNC
Compatibility
• MPS150, EPS150, all PA/PM stations (except MicroAlign) +
DPP2xx-S, DPP3xx-S, DPP450-S (and former PH110, PH120,
PH150, PH400)
133838 — Front Plate for DC Arms
on RPP2xx Positioners
Features
• Used for mounting DC Arms for ope n
systems on RPP2xx RF positioners
• RF arm must be disassembled from the
RPP2xx positioner
Specifications
• Used to moun t 1 (each) of 100489/100524/100525/100560/
100561/100696/100715/131844
• Not for use with 144139
Compatibility
• EPS150/200, PM8, PA200, PM300 + RPP2xx
144139 — Probe Arm, DPP2xx/DPP3xx,
Flex, DCP Probes
Features
• High rigidity
• Stainless steel design for high rigidity and
minimum thermal drift
• Requires adaptation unit 138697 for use with
DPP3xx/DPP450
• DCP probes, cables and conn ectors not included base
Compatibility
• MPS150, EPS150, all PA/PM open systems (exce pt MicroAlign) +
DPP2xx-S, DPP3xx-S, DPP450-S (and former PH110, PH150,
PH400)
Note: DPP3xx-S and DPP450-S (and former PH15 0, PH400) require
138697 in order to mount this arm.

PN 141-400 www.formfactor.com Probe Mounts/Holders and Probes • 105
Revision 57, February, 2023 Probe Station Accessories
RF PROBE ARMS, RPP210-S
146041 — Probe Arm, RPP210-S, North-South, for
Vacuum/Magnetic Platen
Features
• For use with HF probes (e.g., |Z| Probe)
• Positions the probe at the front or rear side of
DUT
• Horizontal probe mounting platen can be
leveled
• For use with vacuum and magnetic platen
Compatibility
• MPS150, EPS150, all PA/PM stations (except MicroAlign) +
RPP210-S (and former PH110)
• Arms are not compatible with EPS200RF, EPS20 0MMW, or PM8
with RF or MMW platen. For these systems, the platen adapter
(PN 1 00651) is required, or you may consult a FormFactor
representative for custom arms.
146042 — Probe Arm, RPP210-S, East-West, for
Vacuum/Magnetic Plate
Features
• For use with HF probes (e.g., |Z| Probe)
• Positions the probe at the left or right side of
DUT
• Horizontal probe mounting platen can be
leveled
• For use with vacuum and magnetic platen
Compatibility
• MPS150, EPS150, all PA/PM stations (except MicroAlign) +
RPP210-S (and former PH110)
• Arms are not compatible with EPS200RF, EPS20 0MMW, or PM8
with RF or MMW platen. For these systems, the platen adapter
(PN 1 00651) is required, or you may consult a FormFactor
representative for custom arms.
RF PROBE ARMS, RPP305
100624 — Probe Arm, RPP305, East-West, Mirrored
Features
• For use with HF probes (e.g., |Z| Probe)
• For positioning the probe on the left or right side
of DU T
• Probe mounting platen ca n be leveled
• Mirror image of 100648 (only for 2 port
configuration in combination with 100648)
Compatibility
• MPS150, EPS150, all PA/PM stations (except MicroAlign) +
RPP305-S (and former PH25 0)
100647 — Probe Arm, RPP305, East
Features
• For use with HF probes (e.g., |Z| Probe)
• For positioning the probe on the right side of
DUT
• Probe mounting platen ca n be leveled (not
compatible with 4-port configuration)
Compatibility
• All PA/PM stations (except MicroAlign) + RPP305-S (and former
PH250)
100648 — Probe Arm, RPP305, East-West
Features
• For use with HF probes (e.g., |Z| Probe)
• For positioning the pr obe on the left or right side
of DU T
• Probe mounting platen ca n be leveled
• Mirror image of 100624 (for 4-port c onfiguration,
for 2-port configuration with 100624)
Compatibility
• MPS150, EPS150, all PA/PM stations (except MicroAlign) +
RPP305-S (and former PH25 0)