PN 141-400 www.formfactor.com Probe Mounts/Holders and Pro bes • 1 15 Revision 57, February, 2023 Probe Station A ccessories 145 30 1 — P r ob e HV Coa x / Kel vin / 3 kV D ANGER T o use this pr obe safely , y our statio…

100%1 / 169
PN 141-400 www.formfactor.com Probe Mounts/Holders and Probes 114
Revision 57, February, 2023 Probe Station Accessories
PROBES, PM5 POWER SYSTEMS
142693 Probe 10 kV
DANGER
To use this probe safely, your station must be configured with a
Tesla specific light curt ain or approved sa fety interlocks. Failure to
employ these safety measures can result in serious injury or death.
Features
Highly isolated needle clamp for
standard single tips
Stainless steel design for h igh rigidity
and minimum thermal drift
For use with temperature chucks up to
300°C (572°F)
Requires arm holder for RPP210
Specifications
1.2 m (4 ft) coax cable with 10 kV plug
Operating voltage up to 10 kV
Compatibility
PM5 Power
145297 Probe HV Triax / 3 kV
DANGER
To use this probe safely, your station must be configured with a
Tesla specific light curt ain or approved sa fety interlocks. Failure to
employ these safety measures can result in serious injury or death.
Features
Highly isolated needle clamp for
standard single tips like PTT needles
For use with temperature chucks up to
300°C (572°F)
Stainless steel design for h igh rigidity
and minimum thermal drift
Requires arm holder for RPP210
Specifications
1.2 m (4 ft) coax cable with HV triax plug
Operating voltage up to 3 kV with lowest leakage
Compatibility
PM5 Power
145298 Probe HV Coax / 3 kV
DANGER
To use this probe safely, your station must be configured with a
Tesla specific light curtain or approved safe ty interlocks. Failure to
employ these safety measures can result in serious injury o r death.
Features
Highly isolated needle clamp for standard
single tips
Stainless steel design for high rigidity and
minimum thermal drift
For use with temperature chucks up to
300°C (572°F)
Requires arm holder for RPP210
Specifications
0.75 m (2.5 ft) coax cable with SHV plug
Operating voltage up to 3 kV
Compatibility
PM5 Power
145300 Probe HV Triax / Kelvin / 3 kV
DANGER
To use this probe safely, your station must be configured with a
Tesla specific light curtain or approved safe ty interlocks. Failure to
employ these safety measures can result in serious injury o r death.
Features
For triaxial I/V and Kelvin
measurements
Highly isolated needle clamp for
standard single tips
Stainless steel design for high rigidity
and minimum thermal drift
For use with temperature chucks up to 300°C (572°F)
Connector sockets for CommonRing cables
Requires arm holder for RPP210
Specifications
2 x 1.2 m (4 ft) 50 Ohm triaxial c able with HV Triax plug
Operating voltage up to 3 kV
Compatibility
PM5 Power
PN 141-400 www.formfactor.com Probe Mounts/Holders and Probes 115
Revision 57, February, 2023 Probe Station Accessories
145301 Probe HV Coax / Kelvin / 3 kV
DANGER
To use this probe safely, your station must be configured with a
Tesla specific light curt ain or approved sa fety interlocks. Failure to
employ these safety measures can result in serious injury or death.
Features
For coaxial I/V-, Kelvin- and C/V te sts
Highly isolated needle clamp for
standard single tips
Stainless steel design for h igh rigidity
and minimum thermal drift
For use with temperature chucks up to
300°C (572°F)
Connector sockets for CommonRing cables
Requires arm holder for RPP210
Specifications
2 x 1.2 m (4 ft) 50 Ohm coaxial cable with SHV plug
Operating voltage up to 3 kV
Compatibility
PM5 Power
145302 Probe Coax / Kelvin
Features
For coaxial I/V-, Kelvin- and C/V te sts
Highly isolated needle clamp for single
tips (inner conductor of both cables
already connected inside chassis)
Stainless steel design for h igh rigidity
and minimum thermal drift
For use with temperature chucks up to 300°C (572°F)
Connector sockets for CommonRing cables
Requires arm holder for RPP210
Specifications
2 x 1.2 m (4 ft) 50 Ohm coaxial cable with BNC connector
Compatibility
PM5 Power
146083 Sigma for B1505A/SE
DANGER
To use this probe safely, your station must be configured with a
Tesla specific light curtain or approved safe ty interlocks. Failure to
employ these safety measures can result in serious injury o r death.
Features
SIGMA Integration of Keysight B1505A
Parameter System into the
ShieldEnclosure/POWER, including:
On-wafer integration of Keysight
B1505A Parameter Analyzer System for
high voltage measurements up to 3 kV
and for high current measurements up
to 20 A pulsed
Optimal integration by EMI and light
shielded environment
Dedicated probe a rm set of 11
probe arms (triax, coax, Kelvin/triax,
Kelvin/coax) for measuring with
highest accuracy of:
Lateral and vertical devices
IV like device break down /I leak
CV like Cds and Cgd
All appropriate feedthroughs,
internal system wiring,
measurement adapter and supports
to accommodate Keysight
protection adapters and HV-bias-T
according to the Application
Overview for B1505A by Keysight
Keysight-verified configuration and
probe accessories
Also requires:
3 DPP2xx-M positioners wit h
MAG base
Standard probe needles s uitable
for desired voltage/ current range
Compatibility
PM5 Power System
PN 141-400 www.formfactor.com Probe Mounts/Holders and Probes 116
Revision 57, February, 2023 Probe Station Accessories
146151 Mounting B1505A/Module Selector/SE
DANGER
To use this probe safely, your station must be configured with a
Tesla specific light curt ain or approved sa fety interlocks. Failure to
employ these safety measures can result in serious injury or death.
Features
Feed-through for an Keysight N1258A
Module Selector into a ShieldEnclosure for
a Power probe system
Minimum additional space outside the SE
required
Mounting in the rear side o f the SE.
Compatibility
PM5 Power System