141-400-57-probestationaccessoriescatalog - 第141页

PN 141-400 www.formfactor.com Probe Mounts/Holders and Pro bes • 1 25 Revision 57, February, 2023 Probe Station A ccessories 114 -8 43 — Need le Pr obe Mo un t and Ja ck Loc k Hol de r fo r MS1 Ser ies Pos iti oner s Fea…

100%1 / 169
PN 141-400 www.formfactor.com Probe Mounts/Holders and Probes 124
Revision 57, February, 2023 Probe Station Accessories
Summit DC Probe Arms and Mounts
104-030K DCP Probe Mount, Dual Triax Adapter
(Kelvin) for RPP305-EW-SU positioner
Features
Ena bles Kelvin connection to DCP style
probes on East/West RPP305
positioners
Sup ports Summit 11/12K and S300
systems
Specifications
Instrument connections are female mini-
triax connectors
Probe connections are ca bles with
SSMC male fo r use with DCP style probes
Usa ble from -60°C to +300°C (-140° to +572°F, above +250°C
[+482°F]: 8 hours max. operation)
50 Ohm characteristic impedance
Breakdown voltage: >500Vo lts
Max curren t = 1Amp
Kit Contents
Mounting hardware
Compatibility
Summit, S300, Alessi
104-856K DCP Probe Mount, Dual Triax Adapter
(Kelvin) for RPP305-NS-SU Positioner
Features
Ena bles Kelvin connection to DCP style pr obes on North/South RF
positioners
Sup ports Summit 11/12K and S300 systems
Specifications
Instrument connections are female mini-triax c onnectors
Probe connections are ca bles with SSMC male for use with DCP
style probes
Usa ble from -60°C to +300°C (-140° to +572°F, above +250°C
[+482°F]: 8 hours max. operation)
50 Ohm characteristic impedance
Breakdown voltage: >500Vo lts
Max curren t = 1Amp
Kit Contents
Mounting hardware
Compatibility
Summit, S300, Alessi
114-818 DCP Probe Mount, Dual Triax Adapter
(Kelvin) for DPP2xx
Features
Enables Kelvin connection to DCP style
probes on DPP2xx positioners
Supports Summit 11/12K and S300
systems
Specifications
Instrument connections ar e female mini-
triax connectors
Probe connections are cables with SSMC
male for use with DCP style probes
Usable from -60°C to +300°C (-140° to +572°F, above +250°C
[+482°F]: 8 hours max. operation)
50 Ohm characteristic impedance
Breakdown voltage: >500Volts
Max current = 1Amp
Kit Contents
Mounting hardware
Compatibility
Summit, S300, Alessi
114-842 Needle Probe Mount and Jack Lock Holder
for DPP2xx
Product Features
Enhanced probe mount for PTT
needle probes (45°)
Easy p robe needle replacement
without any tools
Top hat compatible
Will work on positioners
equipped for DCP probes
Uses mini p in jack style or SSMC
cable connection
Kit Contents
Includes arm and mounting hardware
Recommended for use with PTT-XX/4-25 (45°) style needles (not
included)
Stat ion Compatibility
Summit, S300, Alessi
PN 141-400 www.formfactor.com Probe Mounts/Holders and Probes 125
Revision 57, February, 2023 Probe Station Accessories
114-843 Needle Probe Mount and Jack Lock Holder
for MS1 Series Positioners
Features
Needle probe h older (PTT style
needles) for MS1 series
programmable positioners
Jack lock style holding mechanism
Top hat compatible
Will work on positioners equipped for
DCP probes
Use s mini pin jack style cable
connection
Kit Contents
Includes arm and mounting hardware
Rec ommended for use with PTT-XX/4-25 (45degree) style needles
(not included)
Compatibility
Summit, S300, Alessi
114-847 Needle Probe Mount and Jack Lock Holder
for MH2 Positioners
Features
Needle probe h older (PTT style
needles) for MH2 series positioners
Jack lock style holding mechanism
Top hat compatible
Will work on positioners equipped for
DCP probes
Use s mini pin jack style cable
connection
Kit Contents
Includes arm and mounting hardware
Rec ommended for use with PTT-XX/4-25 (45degree) style needles
(not included)
Compatibility
Summit, S300, Alessi
115-596 DCP Probe Mount, Dual Triax Adapter
(Kelvin) for MS1 Series Positioners
Features
Enables Kelvin connection to DCP style
probes on MS1 series programmable
positioners
Specifications
Instrument connection are female mini-triax
connectors
Probe connections are cables with SSMC
male for use with DCP style probes
Usable from -60°C to +300°C (-140° to +572°F, above +250°C
[+482°F]: 8 hours max. operation)
50 Ohm characteristic impedance
Breakdown voltage: >500Volts
Max current = 1Amp
Kit Contents
Mounting hardware
Compatibility
Summit, S300, Alessi
116-031 DCP Probe Mount for DPP2xx, Direct Probe/
Cable Conn (SSMC)
Features
Mounting bracket for DCP probes, for
use on DPP2xx positioners
To be used wi th direct cable from
instrument to DCP probe (e.g., 105-540
or 124-562 BNC to SSMC cables
Top Hat compatible
Kit Contents
Mounting hardware
Compatibility
Summit, S300, Alessi
PN 141-400 www.formfactor.com Probe Mounts/Holders and Probes 126
Revision 57, February, 2023 Probe Station Accessories
129-116 PTT Probe Mount (MMP-01/J) and Adapter
Kit for DPP2xx
Features
For use with DPP2xx positioners
Brass needle holder can be user-
formed as nee ded
Use s pin jack style connection
(e.g., MAE cables), one included
Has gross Z adjustment v ia
thumb screw on holder arm
Holder also pivots
Not recommended for Top Hat use
Kit Contents
Mounting hardware
Mounting bracket
Probe holder arm
MAE-44/18 cable 46 cm (18 in)
Compatibility
Summit, S300 (non TopHat), Alessi