00197463-03_SM_CPP_Customer_EN - 第101页

8 Screwed joint, silencer and holding circuit 8.4 Replacing the holding circuit Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018 101 8.4 Replacing the holding circuit NOTICE Observe the head version Different holdi…

100%1 / 120
8 Screwed joint, silencer and holding circuit
8.3 Silencer
100 Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018
Installation
Fig.169: Attaching the retaining clips
Two-part silencer only:
Fasten the new silencer with two retaining clips.
Always fit the retaining clips from above(1).
Make sure that the retaining clips and the plastic
part of the silencer are flush with one another(2).
 CAUTION!
Only fit the silencer when it has been removed.
.
Fig.170: Inserting the silencer with holding circuit housing
Insert the silencer together with the holding circuit
housing into the start and rotate this until the
holding circuit housing visibly engages in the
holding circuit below.
Check: if you hold the silencer tight and turn the
star, the holding circuit housing inside the silen-
cer should also turn.
Follow the removal instructions in reverse order for further installation.
Also observe the installation instructions in the following sections:
8.2 "Replacing the screwed joint" [}94]
5.1 "Replacing the front plate [03061102-xx]" [}35]
Observe in particular the torques specified!
8 Screwed joint, silencer and holding circuit
8.4 Replacing the holding circuit
Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018 101
8.4 Replacing the holding circuit
NOTICE
Observe the head version
Different holding circuits are used for the SIPLACE CPP heads up to version 04 and those
from version 05 onwards.
Relevant differences for removal and installation work will be mentioned.
Parts, equipment and tools
Select the required holding circuit:
Up to version 04: holding circuit assembly CPP [03055424‑xx]
From version 05: holding circuit assembly CPP [03081381‑xx] (with integrated silencer)
Replace any defective seals, where required:
Seal kit for holding circuit / CPP [03095007‑xx]
Keep any seals which are not needed.
Overview
Observe the following section:
8.1 "Overview of screwed joint, holding circuit and seals" [}93]
Preparation
Remove the head from the machine. For details about removing and fitting the placement
head, refer to the service manual for your machine.
fit the head on the head mount [03056231‑xx].
Make sure that the component sensor protective cap is fitted.
1.1.3 "Protecting the component sensor" [}8]
Removal
If required, dismantle the front plate.
5.1 "Replacing the front plate [03061102-xx]" [}35]
Remove the screwed joint.
8.2 "Replacing the screwed joint" [}94]
Fig.171: Flexprint cable
 CAUTION!
Take care not to damage the Flexprint cable.
.
8 Screwed joint, silencer and holding circuit
8.4 Replacing the holding circuit
102 Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018
Fig.172: Holding circuit
Remove the six screws(1) fastening the holding
circuit.
Screw the screwed joint back into the holding cir-
cuit thread and carefully pull out the holding cir-
cuit.
Fig.173: Removing the holding circuit
Remove the holding circuit with the help of the
screwed joint.
Installation
NOTICE
Seals
When you fit a cleaned holding circuit, used new seals from the holding circuit seal set
[03095007-xx]. Keep the remaining seals safe.
Fig.174: Holding circuit seal
Fit the seal into the holding circuit. Pay attention
to the correct fitting position of the pin.