9 Intermediate distributor and vacuum sensor 9.2 Replacing Intermediate Distributors 1 and 2 108 Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018 Fig.182: Intermediate distributor 1 1. Intermediate distributor 1 (…

100%1 / 120
9 Intermediate distributor and vacuum sensor
9.2 Replacing Intermediate Distributors 1 and 2
Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018 107
9.2 Replacing Intermediate Distributors 1 and 2
NOTICE
Same procedure
The procedure is the same for ID 1 and ID2. Any relevant differences will be mentioned.
Parts, equipment and tools
Select the part required:
Board ID1 (intermediate distributor1)
CPP: [03065295‑xx]
CPP M: [03155680‑xx]
Board ID2 (intermediate distributor2)
CPP / CPP M: [03052586‑xx]
Overview
Fig.181: Intermediate distributor 1 and 2
The intermediate distributor (ID) consists of two
boards:
1. The ID1 is fitted to the front side of the head.
2. The ID2 incl. "KE control board ID2" (rucksack
board) is fitted on the left, to the side of the head.
Description of boards:
9.2.1 "Intermediate distributor ZV1/CPP
[03065295-xx] " [}110]
9.2.2 "Intermediate distributor ZV2/CPP
[03052586-xx] " [}111]
Intermediate distributor function:
LEDs show the operating voltages at the head
and the sensor states
Test connector for the track signals and test pins
for analog signals
Controlled power supply for incremental encoder
from Z and star drive
Interface for component sensor, vacuum unit, va-
cuum sensor of holding circuit and EEPROM
Startup control for the return cylinder
9 Intermediate distributor and vacuum sensor
9.2 Replacing Intermediate Distributors 1 and 2
108 Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018
Fig.182: Intermediate distributor 1
1. Intermediate distributor 1 (ID1)
2. Five fastening screws
Fig.183: Intermediate distributor 2
1. Intermediate distributor 2 (ID2)
2. KE control board ID2
3. Four fixing screws
 NOTICE!
To remove the screw (3a), first dismantle and re-
move the KE control board for ID2 (2).
.
Preparation
Remove the head from the machine. For details about removing and fitting the placement
head, refer to the service manual for your machine.
fit the head on the head mount [03056231‑xx].
Make sure that the component sensor protective cap is fitted.
1.1.3 "Protecting the component sensor" [}8]
Removal
For ID2 only: Dismantle and remove the KE control board ID2.
9.1 "Replacing the KE Control Board ZV2 [03073355-xx]" [}105]
Disconnect all connectors from the board. You may want to mark their positions, to make
clear assignment easier later on.
Remove the screws fastening the board (ID1:5x, ID2:4x).
Carefully lift off the board. Take care not to damage the press-fit connection to the other ID.
9 Intermediate distributor and vacuum sensor
9.2 Replacing Intermediate Distributors 1 and 2
Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018 109
Installation
Follow the removal instructions in reverse order for further installation.
Also observe the installation instructions in the following section:
9.1 "Replacing the KE Control Board ZV2 [03073355-xx]" [}105]
Fig.184: Checking the status and function of the heads
Only when replacing ID1:
After the machine has been restarted write the cali-
bration values from the machine data to the head EE-
PROM. To do so, proceed as follows:
Click the
button.
Click the
button.
Select the head.
Click the
button.
Click on the button Write calibration data to EE-
PROM.