00197463-03_SM_CPP_Customer_EN - 第59页

5 Front plate, star, Z axis and smoothed distributor disc 5.5 Replacing the Single Core Solution (SCS)[03054790Sxx] (only for heads fromFS05) Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018 59 Statuses of LED (RD…

100%1 / 120
5 Front plate, star, Z axis and smoothed distributor disc
5.5 Replacing the Single Core Solution (SCS)[03054790Sxx] (only for heads fromFS05)
58 Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018
5.5.1 Power module for 12 DP drives [03054771‑xx]
Overview
Fig.91: 03054771-02
LED [03054771-02]
LED Color Status Function LED Color Status Function
H1 RD See status
table
DP1 H15 RD See status
table
DP8
H2 GN H16 GN
H3 RD See status
table
DP2 H17 RD See status
table
DP9
H4 GN H18 GN
H5 RD See status
table
DP3 H19 RD See status
table
DP10
H6 GN H20 GN
H7 RD See status
table
DP4 H21 RD See status
table
DP11
H8 GN H22 GN
H9 RD See status
table
DP5 H23 RD See status
table
DP12
H10 GN H24 GN
H11 RD See status
table
DP6 H25 GN ON +24VDC
H12 GN H26 GN ON +5VDC
H13 RD See status
table
DP7 H27 GN ON +3.3VDC
H14 GN
5 Front plate, star, Z axis and smoothed distributor disc
5.5 Replacing the Single Core Solution (SCS)[03054790Sxx] (only for heads fromFS05)
Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018 59
Statuses of LED (RD) and LED (GN) [03054771-02]
Status LED RD Status LED GN Description
Flashing alternately with high frequency Download Z down sensor
Flashes OFF Application for Z down sensor missing (Bios act-
ive)
ON OFF Error in application 2, e.g. leff error
Flashes OFF Z down sensor not initialized
Flashes ON DP is referenced, but ACK error signaled from Z
down sensor
OFF OFF Z down sensor: no communication
OFF ON DP drive operation while positioning
OFF Flashes Z down sensor ready, but drive not referenced
Flashes rapidly OFF Reserved
OFF Flashes rapidly Reserve
NOTICE
No voltage
No voltage is present, when the statuses of LED RD, LED GN or the 7-segment display are
OFF.
7-segment display status H38 [03054771-02]
Display Status Comment
BIOS
0 Init
b Mapping
ERR1 IRAM HW error
ERR2 XRAM HW error
ERR3 CHKS HW error
ERR4 RAM HW error
| Baud rate recognition Waiting for telegram
b (flashes) . No application
|- (flashes) -| Waiting time prior to application access On SCS close to 0, due to
faster start-up
A Application has been started
Download
E Delete CAN download
Rotate segments Load CAN download
P Program CAN download
Application
0 Check FPGA and DSP codes
||| sequential Code errors FPGA or DSP Code missing or inconsistent
|| 2 sequential Error when initializing FPGA HW error while loading
8 Download machine data to APP2
. (flashing) Normal operation
A three-digit error num-
ber, sequential
Operating system error (OSE)
5 Front plate, star, Z axis and smoothed distributor disc
5.5 Replacing the Single Core Solution (SCS)[03054790Sxx] (only for heads fromFS05)
60 Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018
Display Status Comment
081 Too may nodes User defined errors
082 Unknown GSM
083 Communication error
097 CAN ID existing
098 CAN ID already initialized
099 GSM initializing error
100 CAN ID too large
101 Wrong CAN ID
102 Wrong number of the sub-system
5.5.2 Control module for 12 DP drives [03054784‑xx]
Fig.92: Board control module
Control module
1. 16-bit processor
2. H1 and H2
3. H3
 NOTICE!
The status LEDs are not visible, as the control
module is located behind the power module!
.
LED [03054784-02]
LED Color Status Signal
name
Description
H1 RD - _RSTOUT Not assembled
H2 GN Flashes _RSTOUT Function display, application 1 (µController)
H3 GN Flashes N7 FPGA function display
H4 GN Flashes M14 Function display, application 2 (DSP)