00197463-03_SM_CPP_Customer_EN - 第61页
5 Front plate, star, Z axis and smoothed distributor disc 5.5 Replacing the Single Core Solution (SCS)[03054790Sxx] (only for heads fromFS05) Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018 61 5.5.3 Troubleshooti…

5 Front plate, star, Z axis and smoothed distributor disc
5.5 Replacing the Single Core Solution (SCS)[03054790Sxx] (only for heads fromFS05)
60 Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018
Display Status Comment
081 Too may nodes User defined errors
082 Unknown GSM
083 Communication error
097 CAN ID existing
098 CAN ID already initialized
099 GSM initializing error
100 CAN ID too large
101 Wrong CAN ID
102 Wrong number of the sub-system
5.5.2 Control module for 12 DP drives [03054784‑xx]
Fig.92: Board control module
Control module
1. 16-bit processor
2. H1 and H2
3. H3
NOTICE!
The status LEDs are not visible, as the control
module is located behind the power module!
.
LED [03054784-02]
LED Color Status Signal
name
Description
H1 RD - _RSTOUT Not assembled
H2 GN Flashes _RSTOUT Function display, application 1 (µController)
H3 GN Flashes N7 FPGA function display
H4 GN Flashes M14 Function display, application 2 (DSP)

5 Front plate, star, Z axis and smoothed distributor disc
5.5 Replacing the Single Core Solution (SCS)[03054790Sxx] (only for heads fromFS05)
Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018 61
5.5.3 Troubleshooting
Error messages SCS
State LED
red
LED
lamp
green
7-seg. Comment Possible
troubleshooting
solutions
De-energized OFF OFF 8 LEDs and 7-segment
display off
---
Download ZDS Flashes Flashes Red-flashes; green-
flashes alternately at high
frequency
No error
Download SCS (see 7-seg. display) ---
Waiting for baud rate
detection
(baud rate has not
been detected yet)
(see 7-seg. display) ---
Error during baud
rate detection
(see 7-seg. display) ---
CAN error (error
frames)
(see 7-seg. display) ---
SCS application is
missing (BIOS active)
(see 7-seg. display) ---
ZDS application is
missing (BIOS active)
Flashes OFF Red-flashing; green-off Load ZDS
application
Visualization node
number
Not applicable – can be
read on SCS-PCB printed
---
Error in application 2
- error drive, e.g. Ieff
error
ON OFF Red-on; green-off Replace drive if
this occurs multiple
times
Z down sensor not
initialized
Flashes OFF Red-flashing; green-off Memory loss
→ replace the
drive
DP is referenced but
Ack error reported by
ZDS (1).
Flashes ON Red-flashing; green-on Encoder error
→ replace drive
Z down sensor - no
communication
OFF OFF Red-off; green-off Replace the drive
DP drive operation at
positioning
OFF ON Red-off; green-on -> the
drive is in position regula-
tion.
DP _drive OK
DP drive operation at
positioning
OFF OFF Red-off; green-off -> The
drive is currently perform-
ing a task
(no end message).
No error
ZDS is ready for op-
eration, but the drive
has not been refer-
enced
OFF Flashes Red-flashing; green-
flashing
No error
Reserve Flashes OFF Red-flashing; green-off
(rapid)
---
Reserve OFF Flashes red-off; green-flashing
(rapid)
---

5 Front plate, star, Z axis and smoothed distributor disc
5.5 Replacing the Single Core Solution (SCS)[03054790Sxx] (only for heads fromFS05)
62 Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018
Status 7-segment display on the SCS
State Display Comment Possible troubleshoot-
ing solutions
During download E (E)rase, memory will be deleted No error
P (P)rogramming, memory is be-
ing written
No error
Rotating Memory is being loaded No error
BIOS | Waiting for baud rate detection No error
0 Initialization No error
b (B)ios, no application Bootphase Bios
→ no error
A Application has been started No error
ERR1 HW error IRAM Hardware error
→ replace assembly
ERR2 HW error XRAM
ERR3 HW error CHKS
ERR4 HW error RAM
B(flash-
ing).
No application Load application
|-(flash-
ing)-|
Waiting period before jump to
the application,
almost 0 for SCS - due to fast
boot
No error
Application 0 Check FPGA und DSP code No error
8 Download machine data to ap-
plication 2
No error
. (flash-
ing)
Normal status No error
User defined errors
(three-digit number shown
sequentially)
081 Too many friends Incorrect addressing by
SIRIO
→ error message with
bug report
082 Unknown GSM
083 Communication error
097 CAN_ID already exist
098 CAN_ID already initialized
099 GSM initialization error
100 CAN-ID is too big
101 Wrong CAN ID
102 Wrong number of subsystems
OSE error
(three-digit number shown
sequentially)
001 - 079 Operating system error
→ error message with
bug report