80S-2080F480F5 - 第166页

3 Placement Functions SIPLACE 80S-20/F4 /F5 User Manual 3.4 Feeders 05/99 Issue from Software Version SR.405.xx 3 - 26 3.4.2 Om it Components The "Om it compon ents“ fun ction enable s yo u to omit on e or more s pe…

100%1 / 763
SIPLACE 80S-20/F4/F5 User Manual 3 Placement Functions
05/99 Issue from Software Version SR.405.xx 3.4 Feeders
3 - 25
Fig. 3.4.3 Empty tracks with
Component verification with barcode
F
3 Placement Functions SIPLACE 80S-20/F4/F5 User Manual
3.4 Feeders 05/99 Issue from Software Version SR.405.xx
3 - 26
3.4.2 Omit Components
The "Omit components“ function enables you to omit one or more specific components from the PCB and
complete the rest of the placement operation.
PLEASE NOTE
PCBs placed using this function must not be moved automatically into the next station. They must be
removed manually from the output belt.
This function is intended only for introducing a new product.
Click on the
Omit components
button in the "Feeders“ menu.
Fig. 3.4.4 Omit components
The empty tracks are displayed in the "Empty tracks“ menu window. You can then omit any component on any
of the displayed tracks.
Highlight an empty track in the top list and click on the Omit component button.
The "Omitted components with alternative tracks“ window contains the tracks that have been set to "omit-
ted".
Once the PCB has been removed, the omitted components are deleted (this function only applies to one
PCB).
F
SIPLACE 80S-20/F4/F5 User Manual 3 Placement Functions
05/99 Issue from Software Version SR.405.xx 3.4 Feeders
3 - 27
3.4.3 Display Trays and Changing Inventory Levels (Siplace 80F
4
)
In the
Trays
menu you can process inventory levels of the flatpack magazines which have been brought up.
Fig. 3.4.5 Display trays and changing inventory levels
NOTE
Inventory levels are not updated while placement is actually going on.
Click on the
Update inventory levels
button. The current state of the machine will be displayed.
Mark a track.
F