4 Single Functions SIPLACE 80S-20/F4/F5 Us er Manual 4.2 Single Functi ons, Gantry with 12x Revolver Head 05/99 Is sue from Software Version SR.405.xx 4 - 14 4.2.4 V acuum T est, 12x Revolver Head If all n ozzles ar e at…

SIPLACE 80S-20/F4/F5 User Manual 4 Single Functions
05/99 Issue from Software Version SR.405.xx 4.2 Single Functions, Gantry with 12x Revolver Head
4 - 13
4.2.3.4 Head Reference Run
When this function is activated, the z and d axes will carry out a reference run.
Within the working area click on the
Head reference run
button. The z and d axes will carry out a refer-
ence run.
4.2.3.5 Turn D Axis
When this function is activated, you can check the d axis. For the check the d axis is rotated.
Within the working area click on the
Turn d axis
button. The d axis will rotate.
4.2.3.6 Z Axis - Unclamp
When this function is activated, clamping of the z axis will be released.
Within the
Z axis
working area click on the
Unclamp
button. The clamping of the z axis is released and a
message window appears.
To activate clamping click on the
OK
button. The message window will be closed and clamping of the z
axis is active.
4.2.3.7 Vacuum - On
When this function is activated, the vacuum is switched on.
Within the
Vacuum
working area click on the
On
button. The vacuum will be switched on.
4.2.3.8 Vacuum - Off
When this function is activated, the vacuum is switched off.
Within the
Vacuum
working area click on the
Off
button. The vacuum will be switched off.
4.2.3.9 Forced Air - On
When this function is activated, forced air is switched on at the nozzle. At the same time, if vacuum is active it
will be switched off.
Within the Forced air working area click on the On button. Forced air will be switched on.
4.2.3.10 Forced Air - Off
When this function is activated, forced air is switched off at the nozzle.
Within the Forced air working area click on the Off button. Forced air will be switched off.

4 Single Functions SIPLACE 80S-20/F4/F5 User Manual
4.2 Single Functions, Gantry with 12x Revolver Head 05/99 Issue from Software Version SR.405.xx
4 - 14
4.2.4 Vacuum Test, 12x Revolver Head
If all nozzles are at the star, when this function is activated the nozzles will be checked regarding their vacuum
values in the pick-up position.
In the
Gantry functions
menu click on the symbol button for
Vacuum test revolver head.
Fig. 4.2.6 Vacuum test 12x revolver head
Click on the
Measure
button. A head reference run will be carried out and the vacuum values at the pick-
up position measured for all nozzles. The measured values for the open and closed pick-up positions are
displayed.
F

SIPLACE 80S-20/F4/F5 User Manual 4 Single Functions
05/99 Issue from Software Version SR.405.xx 4.2 Single Functions, Gantry with 12x Revolver Head
4 - 15
4.2.5 Nozzle Offset, 12x Revolver Head
This function is used for determining the nozzle height of all segments. If all segments are in the star the value
found here will refer to Segment 1.
In the In the
Gantry functions
menu click on the symbol button for
Nozzle offset
revolver head
.
Fig. 4.2.7 Nozzle offset 12x revolver head
Click on the
Measure
button.
Press the
Start
button when you are asked to do so on the screen. The active gantry will move to a defined
position above the board conveyor and there carry out measurement of the z height with all segments.
Once measurement is finished the gantry will return to its starting position. The measured nozzle heights
will now be displayed.
F