80S-2080F480F5 - 第199页

SIPLACE 80S-20/F4/F5 User M anual 4 Single Functions 05/99 Issue from Software Version SR.405.xx 4.2 Single Functions, Gantry with 12x Revolver Head 4 - 23 4.2.8.1 Confirm Change Set up the no zzles whi ch have to be cha…

100%1 / 763
4 Single Functions SIPLACE 80S-20/F4/F5 User Manual
4.2 Single Functions, Gantry with 12x Revolver Head 05/99 Issue from Software Version SR.405.xx
4 - 22
4.2.8 IC Head Nozzle Changer Configuration (Siplace 80F
4
)
This function is used for displaying, checking and changing the nozzle types in the individual magazines of the
nozzle changer.
In the
Gantry functions
menu click on the symbol button for
Nozzle configuration IC head.
Fig. 4.2.10 Nozzle configuration IC head
- The nozzle garage concerned is shown in the
Garage
column.
- The
Actual
column indicates the actual set-up at the nozzle changer.
- The
Programmed
column indicates the set-up specified by the line computer.
- The
To change
column exhibits an arrow (<== ) when the
Programmed
and
Actual
configurations are
not the same.
F
SIPLACE 80S-20/F4/F5 User Manual 4 Single Functions
05/99 Issue from Software Version SR.405.xx 4.2 Single Functions, Gantry with 12x Revolver Head
4 - 23
4.2.8.1 Confirm Change
Set up the nozzles which have to be changed (in the
To change
column marked with an arrow (<==) in the
individual nozzle garages to the
Programmed
state.
Mark the line in question (it is displayed against a blue background) and within the working area click on
the
Confirm
button.
Programmed
and
Actual
must now be the same.
NOTE
Up to 20 nozzles can be defined.
Each nozzle garage must be confirmed individually.
See also Section 11.2.
4 Single Functions SIPLACE 80S-20/F4/F5 User Manual
4.2 Single Functions, Gantry with 12x Revolver Head 05/99 Issue from Software Version SR.405.xx
4 - 24
4.2.9 Flux Application Unit/Flux (Option for SIPLACE 80F
4
)
The
Go to refill position, Rinse fluxer head
and
Init. fluxer head
buttons
are only active if the flux applica-
tion unit option has been installed. A description of the functions is given in Chapter 11.7 of this User Manual.
Fig. 4.2.11 Flux application unit/flux for SIPLACE 80F
4
(option)
F