80S-2080F480F5 - 第302页
5 Vision Functions SIP LACE 80S-20/F4/F5 Us er Manual 5.5 Teach Fiducial 05/99 Issue from Software Version SR.405.xx 5 - 70 Line en gineer

SIPLACE 80S-20/F4/F5 User Manual 5 Vision Functions
05/99 Issue from Software Version SR.405.xx 5.5 Teach Fiducial
Line engineer 5 - 69
5.5.6.4
PCB onto Center Conveyor
Option
Click on the
PCB to center conveyor
button and the following actions will be executed:
1. There is a board on the input conveyor.
– The conveyor belt starts and conveys the board as far as the stopper.
– The board will be clamped.
2. There is no board on the input conveyor.
– The message appears: ’No PCB on the input conveyor’.
– Insert a board.
– Click on the
PCB to center conveyor
button.
– The conveyor belt starts and conveys the board as far as the stopper.
– The board will be clamped.
NOTE
If there is already a board on the center conveyor, this function will be blocked. You will then see a mes-
sage informing you that there is already a board on the center conveyor.
NOTE
If a twin conveyor is installed you can use the buttons in the option box ’Conv. selection’ to select con-
veyor 1 or conveyor 2.
5.5.6.5
PCB to Output Conveyor
Option
This function will only be executed when there is a board on the center conveyor.
NOTE
When you quit the menu the board will be transported automatically onto the output conveyor.
NOTE
If a twin conveyor is installed you can use the buttons in the option box ’Conv. selection’ to select conveyor 1
or conveyor 2.
5 Vision Functions SIPLACE 80S-20/F4/F5 User Manual
5.5 Teach Fiducial 05/99 Issue from Software Version SR.405.xx
5 - 70 Line engineer
SIPLACE 80S-20/F4/F5 User Manual 5 Vision Functions
05/99 Issue from Software Version SR.405.xx 5.6 Test Component
Line engineer 5 - 71
5.6 Test Component
5.6.1
Test Component
Flow Chart
The
Test component
flow chart shows in graphic form all menu options together with their sub-functions. The
menus are indicated by being bordered with an unbroken line, while the option boxes use a dash-dotted line
and the input boxes a center line.
5.6.2 Information on the
Test Component
Flow Chart
5.6.2.1 Menus
The
Test component
option includes the following menus:
– Select package form
– Test component
The
Save component
name
option box will drop down every time you wish to quit the
Test component
menu having previously generated or modified GF data. This gives you the choice of either saving or discard-
ing the GF data in question.
You can quit the individual menus by clicking on either the icons of another menu or on the
Main view
icon.
5.6.2.2 Input Boxes, Option Boxes
For data input, displaying values and initiating actions the system offers the following input boxes:
– Measure mode
– Adjust contrast sensitivity
– Select component type (80F
4
or 80F
5
machines only)
You can quit the input boxes by clicking on
OK
,
Accept
or
Cancel
.
– Click on
OK
or
Accept
to have the program save the data. The box will then close.
– Click on the Cancel button to discard the data, after which the input box will close.