80S-2080F480F5 - 第350页
5 Vision Functions SIP LACE 80S-20/F4/F5 Us er Manual 5.6 Test Component 05/99 Issue from Software V ersion SR.405.xx 5 - 118 Line en gineer 5.6.4 .16 ‘Size’ measuring mode Click on t he ‘Se tting’ fie ld for the ‘S ize’…

SIPLACE 80S-20/F4/F5 User Manual 5 Vision Functions
05/99 Issue from Software Version SR.405.xx 5.6 Test Component
Line engineer 5 - 117
Grid-driven
(component inspection with the 80F
4
or 80F
5
machines)
The measurement results will provide information on the approximate coordinates and approximate rota-
tion of the component. In addition, you will be informed of the quality of measurement.
Ball-driven
(determining the balls position with the 80F
4
or 80F
5
machines)
The measurement results will provide precise information on the approximate coordinates and approxi-
mate rotation of the component. In addition, you will be informed of the maximum ball offset and the quality
of measurement.
5.6.4.15 Recommendations regarding the Optimum Sequence of Measurement
Methods
The following table contains our recommendations for the optimum sequence of measurement methods for
particular components. The following abbreviations are used:
B = ball-driven
C = corner-driven
G = grid-driven
L = lead-driven
R = row-driven
S = size-driven
*)
L applies to irregularly shaped components with separate windows
Component Measurement sequence
S R G C L B
MELF S L
CHIP S L
SOT S C L
SL
SOJC6 S C
SOJC14 R C
LCC R C L
PLCC R C L
QFP R C L
TAB R C
L
*)
BGA, Flip-Chip S G B
Bare Dies S
Tab. 5.6.1 Optimum sequences of measurement methods

5 Vision Functions SIPLACE 80S-20/F4/F5 User Manual
5.6 Test Component 05/99 Issue from Software Version SR.405.xx
5 - 118 Line engineer
5.6.4.16 ‘Size’ measuring mode
Click on the ‘Setting’ field for the ‘Size’ measuring mode to overlay the
Size measuring mode
menu on the
screen.
Fig. 5.6.35
Measuring mode
option,
Size measuring mode
menu
This menu is used to
– vary the resolution the angle calculation.
– specify the method for the rotation calculation and
– vary the integration settings.
Resolution for the angle calculation
In this measuring mode, if the component rotation has been calculated incorrectly on account of ambiguity,
you can increase the angular resolution in order to determine the angle of rotation. The following increments
may be used in relation to the resolution in order to determine the angle of the components:
– Simple components: Low resolution:
– Complex components: High resolution
Method for calculating the rotation
Here you must specify the number of rotation windows in order to determine the angle:
– Automatic selection
The system selects the number of windows.

SIPLACE 80S-20/F4/F5 User Manual 5 Vision Functions
05/99 Issue from Software Version SR.405.xx 5.6 Test Component
Line engineer 5 - 119
– SWIN method (Single Window)
Selects a single window. This method is suitable for small complex components and fluctuating dimen-
sions.
– TWIN method (Two Windows)
Two windows are selected. This method is particularly suitable for rapid analysis, for PLCCs, for example.
However, this requires the structures to be investigated to lie in the center of the window. If this is not the
case, select just one window (SWIN method).
Integration settings
If you click on the ’Integration settings’ field, the
Integration settings of Size measuring mode
menu will
appear on screen.
Fig. 5.6.36
Measuring mode
option,
Integration settings of Size measuring mode
menu
This menu is used to select the
– integration direction,
– the resolution in the measuring direction and
– the resolution in the integration direction.
Integration direction
In order to determine the angle, select the integration direction towards either the X or Y axis of the compo-
nent. We recommend that you select the longer edge.
Resolution in the measuring direction
Select this resolution in order to optimize the measuring times at the revolver head.