5 Vision Functions SIP LACE 80S-20/F4/F5 Us er Manual 5.6 Test Component 05/99 Issue from Software V ersion SR.405.xx 5 - 120 Line en gineer Resolution in the integration direction Select this re solution in order to opt…

100%1 / 763
SIPLACE 80S-20/F4/F5 User Manual 5 Vision Functions
05/99 Issue from Software Version SR.405.xx 5.6 Test Component
Line engineer 5 - 119
SWIN method (Single Window)
Selects a single window. This method is suitable for small complex components and fluctuating dimen-
sions.
TWIN method (Two Windows)
Two windows are selected. This method is particularly suitable for rapid analysis, for PLCCs, for example.
However, this requires the structures to be investigated to lie in the center of the window. If this is not the
case, select just one window (SWIN method).
Integration settings
If you click on the ’Integration settings’ field, the
Integration settings of Size measuring mode
menu will
appear on screen.
Fig. 5.6.36
Measuring mode
option,
Integration settings of Size measuring mode
menu
This menu is used to select the
integration direction,
the resolution in the measuring direction and
the resolution in the integration direction.
Integration direction
In order to determine the angle, select the integration direction towards either the X or Y axis of the compo-
nent. We recommend that you select the longer edge.
Resolution in the measuring direction
Select this resolution in order to optimize the measuring times at the revolver head.
5 Vision Functions SIPLACE 80S-20/F4/F5 User Manual
5.6 Test Component 05/99 Issue from Software Version SR.405.xx
5 - 120 Line engineer
Resolution in the integration direction
Select this resolution in order to optimize the measuring times at the revolver head.
5.6.4.17 Row’ Measuring mode
Click on the ‘Setting’ field in the
Row measuring mode
menu to call up the following menu:
Fig. 5.6.37
Measuring mode
option,
Row measuring mode
menu
This menu is used to
specify the lead measuring method.
use the package form edges for the rotation windows and/or translation windows.
Measurement
If the inner lead tips are mapped better that the outer tips, for example if a shiny lead is bent upwards slightly,
you can select one of the following options:
measuring the tips via the inner tips of the leads, for bases, for example
Resolution
in the measuring direction
Resolution
in the integration direction
Small components very high very high
Large components with a
measuring step to follow
high medium
SIPLACE 80S-20/F4/F5 User Manual 5 Vision Functions
05/99 Issue from Software Version SR.405.xx 5.6 Test Component
Line engineer 5 - 121
centre of the lead, centre measurement, for PLCC, SOJ, for example
measuring the tips via the outer tips of the leads, for QFP, SOT, SO, for example
Use package form edges
for rotation windows
The package form edges can be used to optimally position the rotation windows. However, to do this, the
package form edge must be visible and it must not contain a row of leads (eg white plugs).
for translation windows
The package form edges can be used to optimally position the translation windows. However, to do this,
the package form edge must be visible and it must not contain a row of leads.
PLEASE NOTE:
Do not use measurement mode Row together with measurement mode Size.
Integration settings
Once you have clicked on the ‘Integration settings’ field, the
Row measuring mode integration settings
menu will appear on screen.
Fig. 5.6.38 Measuring mode option, Row measuring mode integration settings menu
Measuring times can be reduced by lowering the resolution in the measuring or integration direction. How-
ever, you must ensure that the structure to be analysed has a sufficient number of pixels. Otherwise, the mea-
suring quality will be compromised. We recommend to choose the resolution ’High’ or ’Very high’.