80S-2080F480F5 - 第354页

5 Vision Functions SIP LACE 80S-20/F4/F5 Us er Manual 5.6 Test Component 05/99 Issue from Software V ersion SR.405.xx 5 - 122 Line en gineer 5.6.4 .18 ‘Corner ’ measuring mode Click on t he ‘Se tting’ fie ld in the ‘Corn…

100%1 / 763
SIPLACE 80S-20/F4/F5 User Manual 5 Vision Functions
05/99 Issue from Software Version SR.405.xx 5.6 Test Component
Line engineer 5 - 121
centre of the lead, centre measurement, for PLCC, SOJ, for example
measuring the tips via the outer tips of the leads, for QFP, SOT, SO, for example
Use package form edges
for rotation windows
The package form edges can be used to optimally position the rotation windows. However, to do this, the
package form edge must be visible and it must not contain a row of leads (eg white plugs).
for translation windows
The package form edges can be used to optimally position the translation windows. However, to do this,
the package form edge must be visible and it must not contain a row of leads.
PLEASE NOTE:
Do not use measurement mode Row together with measurement mode Size.
Integration settings
Once you have clicked on the ‘Integration settings’ field, the
Row measuring mode integration settings
menu will appear on screen.
Fig. 5.6.38 Measuring mode option, Row measuring mode integration settings menu
Measuring times can be reduced by lowering the resolution in the measuring or integration direction. How-
ever, you must ensure that the structure to be analysed has a sufficient number of pixels. Otherwise, the mea-
suring quality will be compromised. We recommend to choose the resolution ’High’ or ’Very high’.
5 Vision Functions SIPLACE 80S-20/F4/F5 User Manual
5.6 Test Component 05/99 Issue from Software Version SR.405.xx
5 - 122 Line engineer
5.6.4.18 ‘Corner’ measuring mode
Click on the ‘Setting’ field in the ‘Corner’ measuring mode to call up the
Corner measuring mode
menu.
Fig. 5.6.39
Measuring mode
option,
Corner measuring mode
menu
This menu is used to
specify the lead measuring method.
select the number of leads to be measured at each corner.
switch the angle measurement on or off.
Measurement
If the inner lead tips are mapped better that the outer tips, for example if a shiny lead is bent upwards slightly,
you can select one of the following options:
measuring the tips via the inner tips of the leads, for bases, for example
centre of the lead, center measurement, for PLCC, SOI, for example
measuring the tips via the outer tips of the leads, for QFP, SOT, SO, for example
Number of leads to be measured at each corner
If the lead no longer stands out well from the background, in the case of white plugs, for example, use this
option to specify the number of leads to be measured. However, to do this, the component must be fully
described in the line computer (FDC). In this case, there are no further lead measuring steps.
SIPLACE 80S-20/F4/F5 User Manual 5 Vision Functions
05/99 Issue from Software Version SR.405.xx 5.6 Test Component
Line engineer 5 - 123
NOTE
This value should only be modified for special components and plugs. Deactivate lead measurement for white
plugs.
Angle measurement
For single-row components, the angle of rotation is not calculated correctly. Consequently it is better to access
calculation of the angle of rotation in Row measuring mode. Switch off the angle measurement in this option.
5.6.4.19 ‘Lead’ measuring mode
Click on the ‘Setting’ field in the ‘Lead’ measuring mode to call up the
Lead measuring mode
menu.
Fig. 5.6.40
Measuring mode
option,
Lead measuring mode
menu
This menu is used to
specify the lead measuring method.
to select the windows separately for each lead or a combined window for every lead to be measured.
Measurement
If the inner lead tips are mapped better than the outer tips, for example if a shiny lead is bent upwards slightly,
you can select one of the following options: