80S-2080F480F5 - 第393页
SIPLACE 80S-20/F4/F5 User M anual 5 Vision Func tions 05/99 Issue from Software Version SR .405.xx 5.9 Teach Fiducial: Additions with the 80F4 or 80F5 Machines Line en gineer 5 - 161 5.9 T each Fiduci al : Additions with…

5 Vision Functions SIPLACE 80S-20/F4/F5 User Manual
5.8 Recommendation for visually centering components 05/99 Issue from Software Version SR.405.xx
5 - 160 Line engineer
5.8.4 Visually centering flip-chips
5.8.4.1 Setting the parameters on the station computer
Under the ’Illumination’ option in the ’Test component’ menu, select:
– a value of around 50 for the medium illumination plane
– a value of around 20 for the steep illumination plane
5.8.4.2 Recommended sequence of measurements for visually centering bare dies
Measuring mode Size Grid Ball
Settings
Resolution in the measuring direction:
very high
——
Resolution in the integration direction:
very high
——
Tab. 5.8.3 Recommended sequence of measurements for visually centering bare dies

SIPLACE 80S-20/F4/F5 User Manual 5 Vision Functions
05/99 Issue from Software Version SR.405.xx 5.9 Teach Fiducial: Additions with the 80F4 or 80F5 Machines
Line engineer 5 - 161
5.9
Teach Fiducial
: Additions with the 80F
4
or 80F
5
Machines
In contrast to the 80S-20 placement machine the 80F
4
or 80F
5
machine is a single-gantry machine. For this
reason in the
Teach fiducial
menu the
Select gantry
option is permanently set to
Gantry 1
. The
Gantry 2
option cannot be clicked on.
The IC placement head is mounted on the gantry, together with the 12x revolver placement head on the 80F
4
and the 6x revolver placement head on the 80F
5
automatic placement machines. The camera system for
board centering is accommodated on the gantry underside.
All menus with the exception of this option are identical to those of the 80S-20 machine.
A description of the menus and their options will be found in Section 5.5 from Page 5 - 37.
Fig. 5.9.1
Select fiducial
menu,
Select gantry
option
5 Vision Functions SIPLACE 80S-20/F4/F5 User Manual
5.9 Teach Fiducial: Additions with the 80F4 or 80F5 Machines 05/99 Issue from Software Version SR.405.xx
5 - 162 Line engineer