00196613-0102_AI_LP-Dicke6mmDE EN - 第16页
2 Assembly instructions: 6 mm PCB thickness SIPLACE SX1 / SX2 6 mm PCB thickness 06/2009 Edition 16 2.3 Part s required 2.3.1 Assembly kit 2 2.3.2 T ools required – Set of hexagon so cket spanne rs – Set of diagonal cutt…
6 mm PCB thickness 2 Assembly instructions: 6 mm PCB thickness SIPLACE SX1 / SX2
06/2009 Edition
15
2 Assembly instructions:
6 mm PCB thickness
SIPLACE SX1 / SX2
2.1 General
The installation kit is designed for a single conveyor lane.
If you have a dual conveyor, you will have to order this option twice. 2
The installation kit contains optional stoppers. You will need these because printed circuit boards
that are between 0.5 mm and 2.5 mm thick can no longer be stopped reliably with the standard
stopper. You will find more details about installing the optional stoppers in the 00196449 Assembly
Instructions: Optional Stopper. 2
It will take approximately 30 minutes to fit the additional spacers. You will find the time needed to
fit the additional stoppers in the associated instructions. 2
2.2 Restrictions
If the PCB were stopped with the standard stopper, then the minimum thickness of 2.5 mm would
be correct. 2
If the PCB is stopped with the optional stopper, there is no restriction in terms of the minimum
thickness. 2
After conversion, the standard stopper can only stop PCB thicknesses of 2.5 mm to 6 mm. 2
The optional stopper can be used to stop PCBs that are from 0.5 to 6 mm thick. 2
2
2
2

2 Assembly instructions: 6 mm PCB thickness SIPLACE SX1 / SX2 6 mm PCB thickness
06/2009 Edition
16
2.3 Parts required
2.3.1 Assembly kit
2
2.3.2 Tools required
– Set of hexagon socket spanners
– Set of diagonal cutters
– Phillips screwdriver, size 2
– Depth gauge, 200 mm (item no: 03079617-xx)
2
2.3.3 Consumables required
– Cable ties
– Ethyl alcohol
2
2
PCB thickness SIPLACE SX option Item no.: 00519870-xx
1 Spacer bar 519, thickness 2 mm Item no.: 03073321-xx
1 Spacer bar 460, thickness 2 mm Item no.: 03073320-xx
3 Spacer bar 29, thickness 2 mm Item no.: 03073350-xx
1 Stopper option B2_1 Item no.: 03073472-xx
1 Assembly instructions: SIPLACE SX1/SX2 optional stopper Item no.: 00196449-xx
1 Assembly instructions: SIPLACE SX1/SX2 6 mm PCB thickness Item no.: 00196613-xx

6 mm PCB thickness 2 Assembly instructions: 6 mm PCB thickness SIPLACE SX1 / SX2
06/2009 Edition
17
2.4 Safety instructions
WARNING
The safety instructions from the “Operational safety” chapter of the user manual and servicing in-
structions take precedence over these instructions. 2
The SIPLACE placement machines are supplied with main power voltage.
Consequently parts of these systems carry dangerous voltages! This voltage is present at certain
modules inside the machine base, even when the machine is switched off at the main power
switch.
Incorrect handling of the placement machine or touching live parts of the machine can result in
death or severe injury, and considerable damage to equipment.
BEFORE starting any work, shut down the operating system correctly, then switch the machine
OFF at the main power switch and disconnect from the main power supply. In addition, the com-
pressed air supply must be switched off at the compressed air unit's main valve in the machine
base and vented by actuating the needle valve on the compressed air unit.
There is DANGER for heart pacemaker wearers in the vicinity of the linear motors, as described
in detail in the "Special safety instructions for working in the vicinity of strong magnetic fields"
section of the user manual and service manual.
Always follow the accident prevention regulations, DIN or other standards and special safety
rules applicable in your country.
Pay attention to the information concerning residual voltages in the Operational Safety chapter.
Follow the ESD regulations as described in the operational safety section of the operating
instructions.
During the retrofit, always secure the machine to prevent access by other people and to prevent
it being switched on again. The procedure is described in the “Locking the machine…” section of
the user manual.
Working with the SITEST program further increases the risk of accident.
The SITEST program must only be used by authorized and trained personnel.
2
2.4.1 Definitions
2
Please note 2
2
2
2
Caution 2