00190935-01 - 第35页

Nachrüstanleitung/Retrofitting Instructions Pipettenwechsler Siplace 80S15/F3/S20/F4 Nozzle Changer Ausgabe/Edition 03/97 Seite/Page 35 von/of 44 Figure 7: Connecting the power cable of the revolver head nozzle changer t…

100%1 / 43
Pipettenwechsler Siplace 80S15/F3/S20/F4 Nozzle Changer Nachrüstanleitung/Retrofitting Instructions
Ausgabe/Edition 03/97
Seite/Page 34 von/of 44
1.5.1.3 Gantry 2 (Siplace 80S15)
Dismantle the control unit.
Push connecting cable Y0553-W2 through the hole in the machine frame to the compressed air unit
(see figure 5).
Using a suitable tool (e.g. a rod), pull the connecting cable Y0553-W2 from the compressed air unit,
through the machine frame to the terminal panel Y0904.
Push the compressed air hose through the hole in the machine frame to the compressed air unit.
Tie the cable and compressed air hose together with cable lacing.
1.5.1.4 Electrical connections
Guide the connecting cable Y0553-W1 or Y0553-W2 through the cable duct into the terminal panel
Y0904.
Connect terminal Y0553-W1 or Y0553-W2 on the nozzle changer to the terminal panel Y0904 as
shown in the following terminal diagrams (figures 6 and 7).
Please note that there are differences between the Siplace 80S15 and 80F3.
Figure 6: Connecting the power cable of the revolver head nozzle changer to the Siplace 80S15
Nachrüstanleitung/Retrofitting Instructions Pipettenwechsler Siplace 80S15/F3/S20/F4 Nozzle Changer
Ausgabe/Edition 03/97
Seite/Page 35 von/of 44
Figure 7: Connecting the power cable of the revolver head nozzle changer to the Siplace 80F3
Pipettenwechsler Siplace 80S15/F3/S20/F4 Nozzle Changer Nachrüstanleitung/Retrofitting Instructions
Ausgabe/Edition 03/97
Seite/Page 36 von/of 44
1.5.1.5 Connecting the compressed air supply
Figure 8: Connecting the revolver head nozzle changer to the compressed air unit
Attach the connector PK-3 to the free compressed air connection on the back of the compressed air
unit (Siplace 80S15/F3 5.6 bar; Siplace 80S20/F4 5.1 bar).
Attach the compressed air hose from the nozzle changer valve to this connector.
1.5.1.6 Commissioning
The procedure for commissioning the nozzle changer is described in section 1.6.