4 Electrical Section 4-1 4 Electrical Section

3 Mechanical Section
3-32
Specified Lubricants
■ M6e
PART MANUFACTURER PRODUCT NAME
THK AFA Grease
NOK NBU15
X/Y Axis
Ball screw
Linear guide
KYODO YUSHI Multemp
THK AFB Grease
Showa-Shell Albania Grease No. 2
Z/S Axis
Ball screw
Linear guide
Idemitsu Daphnis Eponex Grease No. 2
THK AFB Grease
Showa-Shell Albania Grease No. 2
R Axis
Spline shaft
Idemitsu Daphnis Eponex Grease No. 2
Sumico Lubricant Molybdenum Grease
Three Bond #1901
Showa-Shell Sunlight Grease MB2
R Axis
Gear
Idemitsu Daphne Grease M
NLGI No.2
Silicone Grease for
Nozzle
Three Bond #1855 Silicone Grease
■ MX-20/MXR-20/MX-ST2
PART MANUFACTURER PRODUCT NAME
THK AFB Grease
Showa-Shell Albania Grease No. 2
All axis
Idemitsu Daphnis Eponex Grease No. 2
■Purchasable Grease from i-pulse
Part Name
Part No. Remark
GREASE,AFA LG0-M86A3-00X AFA Grease
GREASE,AFB LG0-M86A4-00X AFB Grease
GUN,GREASE LG0-M86A1-00X Grease Gun and Nozzle set
GREASE,SILICON LG0-M89AB-00X Silicone Grease
NOTE: AFA grease is superior to AFB grease and can be used for all the axes.
NOTE: Order placement for lubricants can be accepted only if the machine is delivered inside Japan. For locations
overseas, please consultant the agency where you purchased the machine.
NOTE: Please specify Part No.
to place an order.

4 Electrical Section
4-1
4
Electrical Section

4 Electrical Section
4-2
Signal I/O
Signal I/O is the abbreviation of signal input/output. The signal input refers to the input signal via the
sensors. The signal output refers to the command transmitted to the actuators.
Signal Output (Control) window serves as controls to move actuators for checking their movements. In
response to their movements, Signal Input (Monitor) window shows On/Off of motors and actuators.
Note: The Signal Input and Signal Out put windows are opened at the same time. You can move actuators using
the Signal Output window while simultaneously checking the signal input status in the Signal Input
window.
Signal Input Monitor
You can check On/Off of the sensors real-time. “1” indicates on, “0” off. When a sensor of a switch, motor,
and actuator responds, the change of the sensor status is shown real-time. Wire disconnection or sensor
failure can also be detected.
Menu: Manual>Signal I/O>Signal Input (Monitor)
These menus allow you to check each sensor status real-time. You can specify the sampling cycle for the
status check.
■ List tab
■ Changing the Sampling Cycle
Action:
① Select Option>SampingCycle.
② Enter sampling cycle (ms) larger than the minimum of 300, and click <OK> button.
③ Select Tool>StartScan to start checking.
④ Select Tool>EndScan to end.
Note: Use the minimum sampling cycle (300) normally.
Note: The combination of an address and bit number (0-7) represents a signal. The name of each signal is shown
in the Details tab.