3-15 AKFEDT -ID Z Clamp Delay T imer 1 [msec] Set the delay time to start the upward movement of the Z clamp after the backup base has started moving up as the second action. Delay T imer 2 [msec] Set the period of time …

100%1 / 343
3-14
AKFEDT-ID
(A01_11)
Input Conveyor
Y Position arrange speed setup (% deceleration) [%]
Set the deceleration rate of the input conveyor Y arrangement speed in
this text box.
(A01_12)
Output Conveyor
Y Position arrange speed setup (% deceleration) [%]
Set the deceleration rate of the output conveyor Y arrangement speed in
this text box.
(A01_13)
PCB locate mode
Stage 1, Stage 2
Operation
"Std" or "Speci cation value" can be selected for the PCB locating
operation.
In normal cases, select "Std".
Std :
The PCB locating operation is performed
according to the standard value speci ed for
the machine.
Speci cation value :
The desired numerical value can be speci ed
for the PCB locating operation.
The 1st sp dclr setting([%] deceleration) [%]
Set the deceleration rate of the backup base movement in this text box.
The speci ed value is re ected for the rst action ( rst one of the two-
step actions) taken in the PCB locating operation. When the locating
operation is released, the value is re ected for the second action.
The 2nd sp dclr setting([%] deceleration) [%]
Set the deceleration rate of the backup base movement in this text box.
The speci ed value is re ected for the second action (second one of
the two-step actions) taken in the PCB locating operation. When the
locating operation is released, the value is re ected for the rst action.
0601-002
1.2 Operation Data
3-15
AKFEDT-ID
Z Clamp
Delay Timer 1 [msec]
Set the delay time to start the upward movement of the Z clamp after
the backup base has started moving up as the second action.
Delay Timer 2 [msec]
Set the period of time during which the Z clamp is released after
completion of component placement. The backup base starts moving
down after this unclamping operation is completed.
Operation waiting time [msec]
Set the waiting time to be spent before the Z clamp is activated.
(A01_14)
Placement mode
(Not Available)
Stage 1, Stage 2
Select either "Placement" or "Pass" as a placement mode for each stage.
In normal cases, select "Placement"
Placement :
The machine is set in the "PLACE" mode.
Pass :
The machine is set in the "PASS" mode.
When "Pass" is set in this text box and the pattern program data is
selected as current one, the vacuum pump is automatically turned off.
0601-002
1.2 Operation Data
3-16
AKFEDT-ID
(A01_15)
Recovery regulation
U-N (Stage 1/Stage 2)
When the placement data is created to cope with the Un-speci ed
multi-model repetitive pattern function, the recovery regulation must be
speci ed.
Reference
Refer to "3.3 Multi-Model Repetitive Patterns" for details.
Disable :
The recovery regulation function is disabled.
The normal automatic recovery function is activated.
Enable :
The recovery regulation function is enabled.
When the automatic recovery function is activated,
a pattern with the smallest "Un" No. is recovered
rst and the subsequent patterns are recovered in the
ascending order.
As long as all components in the pattern (smaller Un
No.) are not recovered, no components are placed for
the subsequent Un No. (unit).
Block Sort (Stage 1/Stage 2)
When placement data is created to cope with the block sorting function
or the block-speci ed multi-model repetitive pattern function, the
recovery regulation function must be enabled.
Note
"Block-Speci ed" means that a control command (0 to 9) is used for
certain data in the placement data (P).
Disable :
The recovery regulation function is disabled.
The normal automatic recovery function is activated.
Enable :
The recovery regulation function is enabled.
When the automatic recovery function is activated,
the components in the group with the smallest block
No. are recovered rst and the components in the
subsequent groups are recovered in the ascending
order.
As long as all components in the group (smaller
block No.) are not recovered, the subsequent group of
components (block No.) are not placed.
0601-002
1.2 Operation Data