3-68 AKFEDT -ID • PEC Recognition Data T able 3C6 PEC recognition function Enable Correction algorithm Standard Zone 1 2 Point Zone 2 Disable Zone 3 Disable Zone 4 Disable Zone 5 Disable Image Disable local Disable Fiduc…

100%1 / 343
3-67
AKFEDT-ID
(2) Creation of Operation Data
PCB Data
Table 3C5
PCB size X (Horizontal) [mm] 330.000
Y(Vertical) [mm] 250.000
T(Thickness) [mm] 1.600
PCB X(Horizontal) [mm] +0.000
origin offset Y (Vertical) [mm] +0.000
Z (deg) [o] +0.00
XY-Angle [deg] [o] +0.00
X-Direction Same
Y-Direction
Z Angular Orientation
PCB height offset [mm] +0.000
Placement Reference
Front Right
PCB locate Sequence
Standard
PCB transfer Sequence
Output Priority
Pre-Placed component Top [mm] 0.000
thickness Bottom [mm] 0.000
PCB transfer speed Input
Between Stages
Output
Input Conveyor Y Position arrange speed setup
(% deceleration)[%]
0
0
PCB locate mode Stage 1 Operation
Std
Stage 2 Operation
Std
Placement mode Stage 1
Placement
Stage 2 Pass
Recovery regulation U-N Stage 1
Disable
Stage 2
Block Sort
Same
Same
Standard
Standard
Standard
Output Conveyor Y Position arrange speed setup
(% deceleration)[%]
Stage 1
Stage 2
Disable
Disable
Disable
0601-002
3.1 Single Pattern (Global Recognition Enabled)
3-68
AKFEDT-ID
PEC Recognition Data
Table 3C6
PEC recognition function Enable
Correction algorithm Standard
Zone 1 2 Point
Zone 2 Disable
Zone 3 Disable
Zone 4 Disable
Zone 5 Disable
Image Disable
local Disable
Fiducial Zone 1 #1 X (Horizontal) FX1
mark Y (Vertical) FY1
Mark Code 1
#2 X (Horizontal) FX2
Y (Vertical) FY2
Mark Code 1
Beam Stage 1 Automatic (1 or 2)
Stage 2 Automatic (3 or 4)
Sequence Stage 1 After Pick Up
Stage 2 After Pick Up
PEC recognition Mode Global
PEC Recognition Mark Data
Table 3C7
Mark
No.
Mark
Size
D1[mm]
1 Round 1.00 0.00 0.00 000.00 05.0 Bright High Standard Standard
(Normal)
Mark
Type
Mark
Size
D2[mm]
Mark
Size
D3[mm]
Angle
[deg]
Window
Size
[mm]
Mark
Image
Mark
Level
Lighting
Level
Coax
Lighting
Level
Ring
Setup Data
Create this data when the automatic setup function is used.
(3) Creation of Placement Head/Nozzle Data
Table 3C8
Nozzle No. Head 1 Head 2 Head 3 Head 4
Nozzle 1 ID Name
Nozzle 2 ID Name
Nozzle 3 ID Name
Nozzle 4 ID Name
Nozzle12 ID Name
HA04
HV03
HA05
HA04
HV03
HA05
HA04
HV03
HA05
HA04
HV03
HA05
0601-002
3.1 Single Pattern (Global Recognition Enabled)
3-69
AKFEDT-ID
(4) Placement Feeder Location Data
Table 3C9
Fdr No. Component ID C Comment Feeder Fixed
Feeder
Alternate
Fdr No.
101 TANA3216C0HIT - Disable Disable 000
103 TR2012-3B0HIT-L2 - Disable Disable 000
105 SOP008-B02SAN32E E Disable Disable 000
(5) P-data (U01)
Unit Control
Table 3C10
Unit Control Offset X [mm] Offset Y [mm] Offset Z [deg] Offset H [mm]
Placement +000.000 +000.000 +000.00 +0.000
Unit PCB Fiducial
Set "Disable" in this text box.
Do not set any parameters in the other text boxes.
P-data
Table 3C11
P-No. X [mm] Y [mm] Z [deg] H [mm] Fdr No. C Comment
1X
1
Y
1
+000.00 +0.000 101 -
2X
2
Y
2
+090.00 +0.000 103 -
3X
3
Y
3
+180.00 +0.000 105 -
4 +000.000 +000.000 +000.00 +0.000 000 E
(6) O-data (U01)
Do not create this data.
0601-002