3OM-1343-008_w.pdf - 第199页

5-14 AKFEDT -ID G: component posture (% of T otal handling errors) Shown are the number of reversed component and polarity judgment errors detected in the recognition process and the percentage of the errors per total nu…

100%1 / 343
5-13
AKFEDT-ID
(13) Warm-up run (Test Mode) time
The running time is counted when the machine is operated under the
following condition.
"Test Mode" is enabled in the "OPERATION MODE" window.
The "PCB Transfer Dsbl." check box is ticked.
(State in which no PCB is put in and out)
(14) Test mode time
Shown is the period of time during which test run was performed
according to the test mode parameters.
(15) Total handling errors/Total components
Shown are the total number of pickup errors, the total number of
components to be picked up, and the percentage of picked components
per total number of pickup errors.
A: comp.missing (% of Total handling errors)
Shown are the number of component missing errors detected by the
linear measure detection sensor and the percentage of component
missing errors per total number of pickup errors.
B: comp. missing (% of Total handling errors)
Shown are the number of component missing errors detected in the
recognition process and the percentage of component missing errors per
total number of pickup errors.
C: comp. vertical (% of Total handling errors)
Shown are the number of vertical component errors detected by
the linear measure detection sensor and the percentage of vertical
component errors per total number of pickup errors.
D: comp. recog. (% of Total handling errors)
Shown are the number of errors detected in the recognition process and
the percentage of errors per total number of pickup errors.
E: comp. thick (% of Total handling errors)
Shown is the percentage of component thickness errors detected by the
linear measure detection sensor per total number of pickup errors.
F: pick-up diff (% of Total handling errors)
Shown are the number of pickup difference errors detected in the
recognition process and the percentage of the errors per total number of
pickup errors.
0607-003
2.1 Machine Performance Data
5-14
AKFEDT-ID
G: component posture (% of Total handling errors)
Shown are the number of reversed component and polarity judgment
errors detected in the recognition process and the percentage of the
errors per total number of pickup errors.
Total handling errors
Shown is the total number of component handling errors.
Zones 1 through 5
1point errors (% of Total PEC recog. errors)
Shown are the total number of errors detected on the rst ducial
mark and the percentage of the detected errors per total number of
all errors detected by the PEC recognition function.
2point errors (% of Total PEC recog. errors)
Shown are the total number of errors detected on the second ducial
mark and the percentage of the detected errors per total number of
all errors detected by the PEC recognition function.
3point errors (% of Total PEC recog. errors)
Shown are the total number of errors detected on the third ducial
mark and the percentage of the detected errors per total number of
all errors detected by the PEC recognition function.
Local ducial errors (% of Total PEC recog. errors)
Shown are the total number of recognition errors in each individual
components and the percentage of the detected errors per total number
of all errors detected by the PEC recognition function.
Total PEC recognition errors
Shown is the total number of errors detected by the PEC recognition
function.
The number of errors detected by the global PEC recognition function
and the total number of errors detected by the BBR recognition function
are displayed.
0607-003
2.1 Machine Performance Data
5-15
AKFEDT-ID
2.2 Handling Errors Per Feeder
When the "Handling Err. Per Fdr" tab is pressed in the "Management Data"
window, the following tab sheet appears inside the window.
Fig. 3E8 "Handling Err. Per Fdr" Tab Sheet
Fig. 3E8-1 "Management Data (Chart)" Window ("Handling Errors per Feeder" Window)
Note
The displayed tab sheet will look different, depending on which option is
selected.
The "Handling Err. Per Fdr" tab sheet is divided further into several tabs and
each tab sheet shows the handling errors per feeder on each individual feeder
bases.
When each tab is pressed, the corresponding tab sheet appears.
0607-003
2.2 Handling Errors Per Feeder